Application of four-dimensional cone beam computed tomography in lung cancer radiotherapy

Author:

Abulimiti Muyasha1,Yang Xu2,Li Minghui2,Huan Fukui2,Zhang Yanxin2,Liang Jun2

Affiliation:

1. National Cancer Center/National Clinical Research Center for Cancer/Cancer Hospital & Shenzhen Hospital,Chinese Academy of Medical Sciences and Peking Union Medical College,Shenzhen,518116,China

2. National Cancer Center/National Cancer Clinical Medical Research Center/National Cancer Hospital of Peking Union Medical College, Chinese Academy of Medical Sciences/Department of Radiotherapy

Abstract

Abstract Objective: This study explored the application of four-dimensional cone beam computed tomography (4D CBCT) in lung cancer patients, seeking to improve the accuracy of radiotherapy and to establish a uniform protocol for the application of 4D CBCT in radiotherapy for lung cancer. Methods: 4D CBCT was applied to evaluate tumor volume response (TVR), motion, and center coordinates during radiotherapy in 67 eligible individuals with lung cancer diagnoses. The differences between 4D CBCT and 3D CBCT in different registration methods were compared. Results: TVR was observed during treatment in 41% of patients (28/67), with a mean volume reduction of 41.7% and a median time to TVR of 19 days. Tumor motion was obvious in 16 patients, with a mean value of 0.52 cm (0.22 to 1.34 cm), and in 3 of 6 tumors close to the diaphragm (0.28 to 0.66 cm). Gray value registration based on mean density projection could still achieve close results to the 4D gray value registration. However, when the registration was based on bone alone, partial off-targeting occurred in the treatment in 41.8% of cases. The off-target rate was 19.0% when the tumor motion was ≤0.5 cm and 52.2% when the motion was >0.5 cm. Conclusion: Tumor volume and motion of intrapulmonary lesions in individuals diagnosed with lung cancer varied significantly in the third week of radiotherapy. 4D CBCT may be more advantageous for isolated lesions without reference to relative anatomical structures or those near the diaphragm. Grayscale registration based on mean density projection is feasible.

Publisher

Research Square Platform LLC

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3