Affiliation:
1. National Cancer Center/National Clinical Research Center for Cancer/Cancer Hospital & Shenzhen Hospital,Chinese Academy of Medical Sciences and Peking Union Medical College,Shenzhen,518116,China
2. National Cancer Center/National Cancer Clinical Medical Research Center/National Cancer Hospital of Peking Union Medical College, Chinese Academy of Medical Sciences/Department of Radiotherapy
Abstract
Abstract
Objective: This study explored the application of four-dimensional cone beam computed tomography (4D CBCT) in lung cancer patients, seeking to improve the accuracy of radiotherapy and to establish a uniform protocol for the application of 4D CBCT in radiotherapy for lung cancer.
Methods: 4D CBCT was applied to evaluate tumor volume response (TVR), motion, and center coordinates during radiotherapy in 67 eligible individuals with lung cancer diagnoses. The differences between 4D CBCT and 3D CBCT in different registration methods were compared.
Results: TVR was observed during treatment in 41% of patients (28/67), with a mean volume reduction of 41.7% and a median time to TVR of 19 days. Tumor motion was obvious in 16 patients, with a mean value of 0.52 cm (0.22 to 1.34 cm), and in 3 of 6 tumors close to the diaphragm (0.28 to 0.66 cm). Gray value registration based on mean density projection could still achieve close results to the 4D gray value registration. However, when the registration was based on bone alone, partial off-targeting occurred in the treatment in 41.8% of cases. The off-target rate was 19.0% when the tumor motion was ≤0.5 cm and 52.2% when the motion was >0.5 cm.
Conclusion: Tumor volume and motion of intrapulmonary lesions in individuals diagnosed with lung cancer varied significantly in the third week of radiotherapy. 4D CBCT may be more advantageous for isolated lesions without reference to relative anatomical structures or those near the diaphragm. Grayscale registration based on mean density projection is feasible.
Publisher
Research Square Platform LLC
Reference15 articles.
1. Cancer statistics in China and United States, 2022: profiles, trends, and determinants;Xia C;Chin Med J,2022
2. NCCN Guidelines Insights: Non-Small Cell Lung Cancer, Version 2.2021;Ettinger D;J Natl Compr Cancer Network: JNCCN,2021
3. Potential of image-guidance, gating and real-time tracking to improve accuracy in pulmonary stereotactic body radiotherapy;Guckenberger M;Radiotherapy and oncology: journal of the European Society for Therapeutic Radiology and Oncology,2009
4. In-treatment 4D cone-beam CT with image-based respiratory phase recognition;Kida S,2012
5. Geometrical differences in gross target volumes between 3DCT and 4DCT imaging in radiotherapy for non-small-cell lung cancer;Li F;J Radiat Res,2013