Affiliation:
1. Department of Exercise Science, High Point University, High Point, NC, USA
2. Department of Kinesiology and Sport Management, Texas Tech University, Lubbock, TX, USA
3. Department of Exercise and Sport Science, The University of North Carolina, Chapel Hill, NC, USA
4. Department of Nutrition, The University of North Carolina, Chapel Hill, NC, USA
Abstract
Abstract
Multi-compartment body-composition models that divide the body into its multiple constituents are the criterion method for measuring body fat percentage, fat mass, and fat-free mass. However, 2- and 3-compartment body-composition devices such as air displacement plethysmography (ADP), DXA, and bioelectrical impedance devices [bioelectrical impedance analysis (BIA)] are more commonly used. Accurate measures depend on several assumptions, including constant hydration, body proportion, fat-free body density, and population characteristics. Investigations evaluating body composition in racial and ethnic minorities have observed differences in the aforementioned components between cohorts. Consequently, for racial/ethnic minority populations, estimates of body composition may not be valid. The purpose of this review was to comprehensively examine the validity of common body-composition devices in multi-ethnic samples (samples including >1 race/ethnicity) and in African-American, Hispanic, Asian, and Native American populations. Based on the literature, DXA produces valid results in multi-ethnic samples and ADP is valid for Hispanic and African American males when utilizing race-specific equations. However, for DXA and ADP, there is a need for validity investigations that include larger, more racially diverse samples, specifically including Hispanic/Latinx, Asian, Native American adults, and African-American females. Technology has advanced significantly since initial validity studies were conducted; therefore, conclusions are based on outdated models and software. For BIA, body-composition measures may be valid in a multi-ethnic sample, but the literature demonstrates disparate results between races/ethnicities. For BIA and ADP, the majority of studies have utilized DXA or hydrostatic weighing as the criterion to determine validity; additional studies utilizing a multi-compartment model criterion are essential to evaluate accuracy. Validity studies evaluating more recent technology in larger, more racially/ethnically diverse samples may improve our ability to select the appropriate method to accurately assess body composition in each racial/ethnic population.
Publisher
Oxford University Press (OUP)
Subject
Nutrition and Dietetics,Medicine (miscellaneous),Food Science
Cited by
37 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献