Blood stream infection and outcomes in recipients of a left ventricular assist device

Author:

Angleitner Philipp1ORCID,Matic Aleksa1ORCID,Kaider Alexandra2,Dimitrov Kamen1,Sandner Sigrid1ORCID,Wiedemann Dominik1ORCID,Riebandt Julia1ORCID,Schlöglhofer Thomas3,Laufer Günther1ORCID,Zimpfer Daniel1ORCID

Affiliation:

1. Division of Cardiac Surgery, Department of Surgery, Medical University of Vienna, Vienna, Austria

2. Center for Medical Statistics, Informatics, and Intelligent Systems (CEMSIIS), Medical University of Vienna, Vienna, Austria

3. Center for Medical Physics and Biomedical Engineering, Medical University of Vienna, Vienna, Austria

Abstract

Abstract OBJECTIVES Our aim was to investigate associations between blood stream infection [≥1 positive blood culture (BC)] and outcomes in recipients of a left ventricular assist device (LVAD). METHODS We retrospectively analysed all adult recipients of a continuous-flow LVAD between 2006 and 2016 at the Division of Cardiac Surgery, Medical University of Vienna (n = 257; devices: Medtronic HeartWare® HVAD®, Abbott HeartMate II®, Abbott HeartMate 3™). The primary outcome was all-cause mortality during follow-up. Secondary outcomes included the risk of stroke and pump thrombus during follow-up as well as the probability of heart transplantation (HTx). Risk factors for the development of ≥1 positive BC were evaluated additionally. RESULTS The incidence of ≥1 positive BC during the first year of LVAD support was 32.1% [95% confidence interval (CI) 26.4–37.9]. Multivariable Cox proportional cause-specific hazards regression analysis showed that a positive BC was associated with significantly increased all-cause mortality [hazard ratio (HR) 5.51, 95% CI 3.57–8.51; P < 0.001]. Moreover, a positive BC was associated with a significantly increased risk of stroke (HR 2.41, 95% CI 1.24–4.68; P = 0.010). There was no association with the risk of pump thrombus or the probability of HTx. Independent risk factors for a positive BC included preoperative albumin and extracorporeal membrane oxygenation/intra-aortic balloon pump support. CONCLUSIONS Blood stream infection is common and associated with a significantly increased risk of all-cause mortality and stroke at any given time during LVAD support. Effective strategies of prevention and treatment are necessary.

Publisher

Oxford University Press (OUP)

Subject

Cardiology and Cardiovascular Medicine,Pulmonary and Respiratory Medicine,General Medicine,Surgery

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3