Morphological and dynamic analysis of the normal aortic valve with 4D computed tomography

Author:

Fikani Amine1ORCID,Craiem Damian2ORCID,Mousseaux Elie3ORCID,Soulat Gilles3ORCID,Rouchaud Aymeric4,Boulogne Cyrille5,Martins Elie5,Jouan Jerome1

Affiliation:

1. Department of Cardiothoracic Surgery, Limoges University Hospital , Limoges, France

2. Instituto de Medicina Traslacional, Trasplante y Bioingeniería (IMeTTyB), Universidad Favaloro-CONICET , Buenos Aires, Argentina

3. Department of Cardiovascular Imaging, Georges Pompidou European Hospital , Paris, France

4. Department of Radiology, Limoges University Hospital , Limoges, France

5. Department of Cardiology, Limoges University Hospital , Limoges, France

Abstract

Abstract OBJECTIVES To evaluate the precise dimensions of the normal aortic root, especially the true aortic annulus, during the cardiac cycle using an innovative reconstruction method based on multiphase cardiac computed tomography and to assess the feasibility and the reproducibility of this method for aortic root analysis. METHODS Between January 2019 and June 2021, 30 optimal consecutive ECG-gated multiphase cardiac computed tomography of patients with normal tricuspid aortic valve were analysed using an in-house software. Aortic annulus border was pinpointed on 9 reconstructed planes and the 3D coordinates of the 18 consecutive points were interpolated into a 3D curve using a cubic spline. Three additional planes were generated at the level of the left ventricular outflow tract, the level of the Valsalva sinus and the level of the sinotubular junction. This procedure was repeated for all the 10 temporal phases of the RR interval. RESULTS The aortic annulus mean 3D and 2D areas were 7.67 ± 1.51 and 5.16 ± 1.40 cm2, respectively. The mean 2D diameter was 2.51 ± 0.23 cm. The mean global area expansion was 11.8 ± 3.5% and the mean perimeter expansion of 7.1 ± 2.6%. During the cardiac cycle, the left ventricle outflow tract expands, reaching its maximum surface at the end of diastole, followed by the aortic annulus, the Valsalva sinuses and the sinotubular junction. The aorta changes from a clover-shaped cone during diastole to more cylindrical shape during systole. Compared to the 3D measurements, the analysis of the virtual basal ring significantly underestimates the annulus area, perimeter, and mean diameter. CONCLUSIONS 4D morphometric analysis enables to have a precise and reproducible evaluation of the aortic annulus. The aortic annulus and root are deformable structures that undergo a unique expansion sequence during the cardiac cycle which should be considered for procedural planning.

Funder

L'ASSOCIATION CHIRURGICALE POUR LE DEVELOPPEMENT ET L'AMELIORATION DES TECHNIQUES DE DEPISTAGE ET DE TRAITEMENT DES MALADIES CARDIO-VASCULAIRES

Publisher

Oxford University Press (OUP)

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3