Comparison of 2 Serum Free Light Chain Assays with Creatinine Normal and Abnormal Populations Demonstrates the Need for Standardization

Author:

Griffiths Mark1,Cheng Pow Lee2,Wang Xiao Yan2,Schneider Randal3,Kulasingam Vathany24

Affiliation:

1. Diazyme Laboratories Inc. , Poway, CA , United States

2. Division of Clinical Biochemistry, University Health Network , Toronto , Canada

3. Abbott Laboratories, Abbott Park , IL , United States

4. Department of Laboratory Medicine and Pathobiology, University of Toronto , Toronto , Canada

Abstract

Abstract Background The objective of this study was to compare The Binding Site’s Freelite on Optilite and Diazyme’s Kappa/Lambda free light chains (K/L FLC) on Abbott Architect c8000 with healthy and renal insufficient populations and to evaluate their respective reference intervals for serum free light chains (sFLCs). Methods Two hundred sixty serum samples were measured for creatinine and sFLCs by both assays and a subset by immunofixation electrophoresis. Verification of manufacturer-defined reference intervals was assessed. Results Kappa free light chains (KFLC) showed excellent correlation of 0.998 R2 with a slope of 0.73. For Lambda free light chains (LFLC), an acceptable correlation of 0.953 R2 was found with a slope of 1.50 as well as a skewness-based difference with a −12.70 intercept. Healthy estimated glomerular filtration rate (eGFR) ≥60 reference interval verification of central 95% could not be confirmed for either Freelite or Diazyme although LFLC was much closer than KFLC for both assays with Freelite KFLC recovering only 37% of values within reference interval claims. The K/L FLC ratio did not meet 100% claim for both Freelite (91%) and Diazyme (95%) among those with eGFR ≥60. Samples with eGFR ≤59 had increasingly higher levels of KFLC and LFLC for both assays. When comparing worsening eGFR status, Freelite recovered increasingly higher ratios while Diazyme recovered increasingly lower ratios. Conclusions Healthy reference intervals could not be verified for either Freelite or Diazyme. Renal reference intervals for Freelite are currently warranted while they are not recommended for Diazyme. The differences between these 2 assays can be minimized by standardization efforts such as recalibration.

Publisher

Oxford University Press (OUP)

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3