Serum Reference Intervals and Diagnostic Ranges for Free κ and Free λ Immunoglobulin Light Chains: Relative Sensitivity for Detection of Monoclonal Light Chains

Author:

Katzmann Jerry A1,Clark Raynell J1,Abraham Roshini S1,Bryant Sandra1,Lymp James F1,Bradwell Arthur R2,Kyle Robert A1

Affiliation:

1. Mayo Clinic, 200 First St. SW, Rochester, MN 55905

2. The Binding Site Ltd and The Medical School, University of Birmingham, Birmingham B15 2TT, England

Abstract

AbstractBackground: The detection of monoclonal free light chains (FLCs) is an important diagnostic aid for a variety of monoclonal gammopathies and is especially important in light-chain diseases, such as light-chain myeloma, primary systemic amyloidosis, and light-chain-deposition disease. These diseases are more prevalent in the elderly, and assays to detect and quantify abnormal amounts of FLCs require reference intervals that include elderly donors.Methods: We used an automated immunoassay for FLCs and sera from a population 21–90 years of age. We used the calculated reference and diagnostic intervals to compare FLC results with those obtained by immunofixation (IFE) to detect low concentrations of monoclonal κ and λ FLCs in the sera of patients with monoclonal gammopathies.Results: Serum κ and λ FLCs increased with population age, with an apparent change for those >80 years. This trend was lost when the FLC concentration was normalized to cystatin C concentration. The ratio of κ FLC to λ FLC (FLC K/L) did not exhibit an age-dependent trend. The diagnostic interval for FLC K/L was 0.26–1.65. The 95% reference interval for κ FLC was 3.3–19.4 mg/L, and that for λ FLC was 5.7–26.3 mg/L. Detection and quantification of monoclonal FLCs by nephelometry were more sensitive than IFE in serum samples from patients with primary systemic amyloidosis and light-chain-deposition disease.Conclusions: Reference and diagnostic intervals for serum FLCs have been developed for use with a new, automated immunoassay that makes the detection and quantification of monoclonal FLCs easier and more sensitive than with current methods. The serum FLC assay complements IFE and allows quantification of FLCs in light-chain-disease patients who have no detectable serum or urine M-spike.

Publisher

Oxford University Press (OUP)

Subject

Biochemistry (medical),Clinical Biochemistry

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3