Evaluating Commutability of Control Materials in Three Nordic External Quality Assessment Schemes for Lipoproteins

Author:

Norling Anna1,Bökman C Fredrik2,Göransson Emma3,Wande Birgitta4,Pedersen Morten M5,Berghäll Heidi6,Svala Emilia1

Affiliation:

1. Equalis AB, Uppsala, Sweden

2. Department of Clinical Chemistry, Laboratory Medicine, Falun Hospital, Falun, Sweden

3. Clinical Chemistry Laboratory, Gävle Hospital, Gävle, Sweden

4. Department of Clinical Chemistry, Uppsala University Hospital, Uppsala, Sweden

5. Danish Institute for External Quality Assurance for Laboratories in Health Care (DEKS), Glostrup, Denmark

6. Labquality Oy, Helsinki, Finland

Abstract

Abstract Background The quality of control materials is crucial for evaluating external quality assessment (EQA) results. To detect method differences, the EQA material should behave the same as a patient sample, meaning the material must be commutable. Noncommutable materials may cause misinterpretations of EQA results. Here, we examined the commutability of EQA materials used in 3 Nordic EQA schemes for lipids. Methods The study was designed according to the procedures recommended for assessing commutability by the International Federation of Clinical Chemistry and Laboratory Medicine. Commutability was assessed based on the difference in bias between a control material (CM) and clinical samples (CS) consisting of human plasma using 2 different measurement procedures (MPs). Measurands: LDL-cholesterol (LDL-C), total cholesterol (TC), HDL-cholesterol (HDL-C), and triglycerides (TG). Four CMs (CM1–4) were assessed for commutability by using 40 CS and 3 MPs (Abbott Architect, Roche Cobas, and Siemens Atellica). Results Unmodified native CMs (CM1 and CM3), stored at −80 °C, were commutable for all included measurands, except for LDL-C that was indeterminate, when comparing MPs pairwise. Modified CM2 was noncommutable for HDL-C, LDL-C, non-HDL-C, and LDL-C calculations. Unmodified native CM4, stored at −20°C, was noncommutable for LDL-C. Conclusions Unmodified serum samples stored at −80 °C were commutable for lipids on the evaluated MPs, and therefore suitable as CMs in EQA schemes. Moreover, the study demonstrated that minor modifications of samples may lead to noncommutability.

Publisher

Oxford University Press (OUP)

Subject

General Medicine

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3