IFCC Working Group Recommendations for Assessing Commutability Part 2: Using the Difference in Bias between a Reference Material and Clinical Samples

Author:

Nilsson Göran1,Budd Jeffrey R2,Greenberg Neil3,Delatour Vincent4,Rej Robert5,Panteghini Mauro6,Ceriotti Ferruccio7,Schimmel Heinz8,Weykamp Cas9,Keller Thomas10,Camara Johanna E11,Burns Chris12,Vesper Hubert W13,MacKenzie Finlay14,Miller W Greg15

Affiliation:

1. Uppsala, Sweden

2. Beckman Coulter, Chaska, MN

3. Neil Greenberg Consulting, LLC, Rochester, NY

4. Laboratoire national de métrologie et d'essais (LNE), Paris, France

5. Wadsworth Center for Laboratories and Research, New York State Department of Health, and School of Public Health, State University of New York at Albany, Albany, NY

6. Research Centre for Metrological Traceability in Laboratory Medicine (CIRME), University of Milan, Milan, Italy

7. Fondazione IRCCS Ca' Granda Ospedale Maggiore Policlinico, Milan, Italy

8. European Commission, Joint Research Centre (JRC), Directorate F, Geel, Belgium

9. Queen Beatrix Hospital, Winterswijk, the Netherlands

10. ACOMED statistic, Leipzig, Germany

11. National Institute of Standards and Technology, Gaithersburg, MD

12. National Institute for Biological Standards and Control, A Centre of the MHRA, Hertfordshire, UK

13. Centers for Disease Control and Prevention, Atlanta, GA

14. Birmingham Quality/UK NEQAS, University Hospitals Birmingham NHS Foundation Trust, Birmingham, UK

15. Department of Pathology, Virginia Commonwealth University, Richmond, VA

Abstract

Abstract A process is described to assess the commutability of a reference material (RM) intended for use as a calibrator, trueness control, or external quality assessment sample based on the difference in bias between an RM and clinical samples (CSs) measured using 2 different measurement procedures (MPs). This difference in bias is compared with a criterion based on a medically relevant difference between an RM and CS results to make a conclusion regarding commutability. When more than 2 MPs are included, the commutability is assessed pairwise for all combinations of 2 MPs. This approach allows the same criterion to be used for all combinations of MPs included in the assessment. The assessment is based on an error model that allows estimation of various random and systematic sources of error, including those from sample-specific effects of interfering substances. An advantage of this approach is that the difference in bias between an RM and the average bias of CSs at the concentration (i.e., amount of substance present or quantity value) of the RM is determined and its uncertainty estimated. An RM is considered fit for purpose for those MPs for which commutability is demonstrated.

Publisher

Oxford University Press (OUP)

Subject

Biochemistry (medical),Clinical Biochemistry

Reference7 articles.

1. IFCC working group recommendations for assessing commutability part 1: general experimental design;Miller;Clin Chem,2018

2. Evaluation of commutability of processed samples; approved guideline,2014

3. Characterization and qualification of commutable reference materials for laboratory medicine; approved guideline,2010

4. Comparison of measurement methods based on a model for the error structure;Nilsson;J Chemometrics,1991

5. Toward standardization of insulin immunoassays;Miller;Clin Chem,2009