COVID-19 mRNA Vaccines May Cause False Reactivity in Some Serologic Laboratory Tests, Including Rapid Plasma Reagin Tests

Author:

Korentzelos Dimitrios1ORCID,Baloda Vandana1,Jung Yujung1,Wheeler Bradley2,Shurin Michael R13,Wheeler Sarah E14ORCID

Affiliation:

1. Department of Pathology, University of Pittsburgh Medical Center , Pittsburgh, PA , USA

2. School of Information and Computing , Pittsburgh, PA , USA

3. Departments of Pathology and Immunology , Pittsburgh, PA , USA

4. Department of Pathology, University of Pittsburgh , Pittsburgh, PA , USA

Abstract

Abstract Objectives Acute viral infections and some vaccines have been shown to increase false positivity in serologic assays. We assessed if the messenger RNA coronavirus disease 2019 (COVID-19) vaccines could cause false reactivity in common serologic assays in a pilot longitudinal cohort. Methods Thirty-eight participants with sera available prevaccination, 2 weeks after each vaccine dose, and monthly thereafter for up to 5 months were tested for common infectious disease serologies and antiphospholipid syndrome (APS) serology markers on the BioPlex 2200, Sure-Vue rapid plasma reagin (RPR), and Macro-Vue RPR. Twenty-two participants received the Moderna vaccine and 16 received the Pfizer vaccine. Results Most assays had no change in reactivity over the course of the sample draws, including APS markers. Epstein-Barr virus immunoglobulin G (IgG), measles IgG, and rubella immunoglobulin M all had possible false reactivity in one to two participants. RPR tests demonstrated false reactivity, with baseline nonreactive participant samples becoming reactive following vaccination. There were more false reactive participants (7/38) in the BioPlex RPR than in the Sure-Vue (2/38) and Macro-Vue (1/38) tests. All falsely reactive RPR tests were in participants who received the Moderna vaccine. Conclusions Serologic assays with results that do not fit the clinical picture following COVID-19 vaccination should be repeated. Effects of false reactivity can last more than 5 months in some assays. In particular, RPR is susceptible to false reactivity, and there is variability among assays. Larger longitudinal studies are needed to determine the incidence and window of false reactivity.

Publisher

Oxford University Press (OUP)

Subject

General Medicine

Reference16 articles.

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3