Cardiovascular magnetic resonance imaging in patients with cardiac implantable electronic devices: best practice and real-world experience

Author:

Seewöster Timm1,Löbe Susanne1,Hilbert Sebastian1,Bollmann Andreas12,Sommer Philipp3,Lindemann Frank1,Bacevičius Justinas1,Schöne Katharina1,Richter Sergio1,Döring Michael1,Paetsch Ingo1,Hindricks Gerhard12,Jahnke Cosima1

Affiliation:

1. Department of Electrophysiology, Heart Center Leipzig at University of Leipzig, Strümpelstr. 39, Leipzig, Germany

2. Leipzig Heart Institute, Russenstraße 69A, Leipzig, Germany

3. Department of Electrophysiology, Herz- und Diabeteszentrum NRW, Georgstraße 11, Bad Oeynhausen, Germany

Abstract

Abstract Aims Cardiovascular magnetic resonance (CMR) imaging has long been a contraindication for patients with a cardiac implantable electronic device (CIED). Recent studies support the feasibility and safety for non-thoracic magnetic resonance imaging, but data for CMR are sparse. The aim of the current study was to determine the safety in patients with magnetic resonance (MR)-conditional or non-MR-conditional CIED and to develop a best practice approach. Methods and results All patients with a CIED undergoing CMR imaging (1.5 T) between April 2014 and April 2017 were included in the study. Devices were programmed according to the standardized protocol directly before and after the CMR examination. Follow-up interrogation was performed 6 months after CMR examination. Results were compared with a large, reference cohort of CIED patients not undergoing any MR examination. A total of 200 consecutive patients with a CIED (non-MR-conditional, n = 103) were included in the study. Directly after CMR imaging, one device failure (0.5%, battery status = end of service) was noted necessitating premature generator replacement. In three patients (2%) of pacemaker/implantable cardioverter-defibrillator (ICD) carriers a sustained ventricular tachycardia (VT) occurred during CMR imaging. Ten ICD showed a decrease in battery capacity immediately after CMR. Overall, the reference cohort showed comparable changes of CIED function during follow-up. Conclusion With adherence to a standardized protocol and established exclusion criteria CMR imaging could safely be performed in patients with a CIED. The potential risks of device malfunction necessitate the presence of a device trained individual during the entire CMR examination. If there is a history of VT storm the attendance of an experienced cardiologist, should be mandatory.

Funder

Abbott

Pfizer

Publisher

Oxford University Press (OUP)

Subject

Physiology (medical),Cardiology and Cardiovascular Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3