Long-term survival following upgrade compared with de novo cardiac resynchronization therapy implantation: a single-centre, high-volume experience

Author:

Schwertner Walter Richard1ORCID,Behon Anett1ORCID,Merkel Eperke Dóra1,Tokodi Márton1ORCID,Kovács Attila1,Zima Endre1,Osztheimer István1ORCID,Molnár Levente1,Király Ákos1,Papp Roland1,Gellér László1,Kuthi Luca1,Veres Boglárka1,Kosztin Annamária1ORCID,Merkely Béla1

Affiliation:

1. Heart and Vascular Centre, Semmelweis University, Városmajor 68, H-1122 Budapest, Hungary

Abstract

Abstract Aims Patients with a pacemaker or implantable cardioverter-defibrillator are often considered for cardiac resynchronization therapy (CRT). However, limited comprehensive data are available regarding their long-term outcomes. Methods and results Our retrospective registry included 2524 patients [1977 (78%) de novo, 547 (22%) upgrade patients] with mild to severe symptoms, left ventricular ejection fraction ≤35%, and QRS ≥ 130ms. The primary outcome was the composite of all-cause mortality, heart transplantation (HTX), or left ventricular assist device (LVAD) implantation; secondary endpoints were death from any cause and post-procedural complications. In our cohort, upgrade patients were older [71 (65–77) vs. 67 (59–73) years; P < 0.001], were less frequently females (20% vs. 27%; P = 0.002) and had more comorbidities than de novo patients. During the median follow-up time of 3.7 years, 1091 (55%) de novo and 342 (63%) upgrade patients reached the primary endpoint. In univariable analysis, upgrade patients exhibited a higher risk of mortality/HTX/LVAD than the de novo group [hazard ratio (HR): 1.41; 95% confidence interval (CI): 1.23–1.61; P < 0.001]. However, this difference disappeared after adjusting for covariates (adjusted HR: 1.12; 95% CI: 0.86–1.48; P = 0.402), or propensity score matching (propensity score-matched HR: 1.10; 95% CI: 0.95–1.29; P = 0.215). From device-related complications, lead dysfunction (3.1% vs. 1%; P < 0.001) and pocket infections (3.7% vs. 1.8%; P = 0.014) were more frequent in the upgrade group compared to de novo patients. Conclusion In our retrospective analysis, upgrade patients had a higher risk of all-cause mortality than de novo patients, which might be attributable to their more significant comorbidity burden. The occurrence of lead dysfunction and pocket infections was more frequent in the upgrade group.

Funder

New National Excellence Program

National Research, Development and Innovation Found of Hungary

NVKP_16 founding scheme

Thematic Excellence Programme

Publisher

Oxford University Press (OUP)

Subject

Physiology (medical),Cardiology and Cardiovascular Medicine