Background. The incidence of infections and death in patients implanted with cardiac implantable electronic devices (CIEDs) is not fully known yet. Aim. To describe the incidence of CIED-related infection and death, and their potential predictors in a contemporary cohort of CIED patients. Methods. All consecutive patients implanted with a CIED at our institution were prospectively enrolled. Follow-up visits were performed 2 weeks after CIED implantation for all patients, and then every 6 months for implantable cardioverter defibrillator (ICD)/cardiac resynchronization therapy (CRT) patients and every 12 months for pacemaker (PM) patients. The adjudication of CIED-related infections was performed by two independent investigators and potential disagreement was resolved by a senior investigator. Results. Between September 2016 and August 2020, a total of 838 patients were enrolled (34.6% female; median age 77 (69.6–83.6); median PADIT score 2 (2–4)). PMs were implanted in 569 (68%) patients and ICD/CRT in 269 (32%) patients. All patients had pre-implant antibiotic prophylaxis and 5.5% had an antibiotic-eluting envelope. Follow-up data were available for 832 (99.2%) patients. After a median follow-up of 42.3 (30.2–56.4) months, five (0.6%) patients had a CIED-related infection and 212 (25.5%) patients died. Using multivariate Cox regression analysis, end-stage chronic kidney disease (CKD) requiring dialysis and therapy with corticosteroids was independently associated with a higher risk of infection (hazard ratio (HR): 14.20; 95% confidence interval (CI) 1.48–136.62 and HR: 14.71; 95% CI 1.53–141.53, respectively). Age (HR: 1.07; 95% CI 1.05–1.09), end-stage CKD requiring dialysis (HR: 6.13; 95% CI 3.38–11.13) and history of atrial fibrillation (HR: 1.47; 95% CI 1.12–1.94) were independently associated with all-cause death. Conclusions. In a contemporary cohort of CIED patients, mortality was substantially high and associated with clinical factors depicting a population at risk. On the other hand, the incidence of CIED-related infections was low.

Publisher

MDPI AG

Subject

General Medicine

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3