A MODEL FOR EVALUATING THE USE OF IMAGING IN IMAGE-GUIDED INTERVENTIONAL PROCEDURES—POSSIBLE IMPLICATIONS ON OPTIMISATION OF RADIATION PROTECTION

Author:

Lundh C12,Ivarsson J3,Falkenberg M4,Båth M12,Almén A56

Affiliation:

1. Department of Medical Physics and Biomedical Engineering, Sahlgrenska University Hospital, SE-413 45, Göteborg, Sweden

2. Department of Radiation Physics, Institute of Clinical Sciences, Sahlgrenska Academy, University of Gothenburg, SE-413 45, Göteborg, Sweden

3. Department of Applied IT, University of Göteborg, SE-412 96, Göteborg, Sweden

4. Department of Radiology, Institute of Clinical Sciences, Sahlgrenska Academy, University of Gothenburg, SE-413 45, Göteborg, Sweden

5. Department of Radiation Protection, Swedish Radiation Safety Authority, SE-171 16, Stockholm, Sweden

6. Medical Radiation Physics, Department of Translational Medicine (ITM), Lund University, SE-205 02, Malmö, Sweden

Abstract

Abstract The present study focuses on introducing the concept of optimisation and proposing a model, including evaluation of image quality, to be used in the clinical routines where image-guided intervention is being performed. The overall aim of the study was to develop a model for evaluating the use of imaging in X-ray-guided interventional procedures and its possible implications on optimisation of radiation protection. In the search for an adequate evaluation model, data from endovascular interventions of the aorta (EVAR procedures) were used. The procedure was schematically described in steps. Every imaging event was connected to the steps in the medical procedure and was also described with the purpose of the imaging event. Available technical, as well as procedural parameters, were studied and analysed. Data were collected from the X-ray equipment for 70 EVAR procedures and, out of these, 12 procedures were randomly selected to be recorded on video to understand the procedure better. It was possible to describe the EVAR procedures in a general way with explanations of the clinical purpose connected to each imaging event. Possible quality parameters of the procedure were identified for the imaging events (radiation dose, image quality). The model method still needs to be refined and will then be applied to clinical data and to other clinical procedures to test the validity.

Funder

Swedish Research Council

Publisher

Oxford University Press (OUP)

Subject

Public Health, Environmental and Occupational Health,Radiology, Nuclear Medicine and imaging,General Medicine,Radiation,Radiological and Ultrasound Technology

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

1. ALIGNING VIDEO-AND STRUCTURED DATA FOR IMAGING OPTIMISATION;Radiation Protection Dosimetry;2021-05-25

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3