AlluraClarity Radiation Dose–Reduction Technology in the Hybrid Operating Room During Endovascular Aneurysm Repair

Author:

de Ruiter Quirina M. B.1,Moll Frans L.1,Gijsberts Crystel M.23,van Herwaarden Joost A.1

Affiliation:

1. Department of Vascular Surgery, University Medical Center, Utrecht, the Netherlands

2. Department of Heart and Lungs, University Medical Center, Utrecht, the Netherlands

3. ICIN-Netherlands Heart Institute, Utrecht, the Netherlands

Abstract

Purpose: To evaluate the effect of radiation dose reduction with the Allura ClarityIQ image processing technology for fixed C-arms in comparison with a mobile C-arm and an Allura fixed C-arm without ClarityIQ technology during endovascular aneurysm repair (EVAR) procedures. Methods: Radiation dose data from 85 patients (mean age 74.2±7.8 years; 68 men) undergoing EVAR with mobile and fixed C-arm fluoroscopy were retrospectively analyzed. The radiation dose parameters included the kerma area product (KAP), fluoroscopic time (FT), and number of digital subtraction angiography (DSA) frames (FrDSA). KAPtotal consisted of KAPfluoro (KAP for fluoroscopic imaging) and KAPDSA (KAP for DSA and single shots). Linear regression analysis was used to explore differences in the association of KAP with the FT, FrDSA, and body mass index (BMI) among the 3 C-arms. Results: The mean KAPtotal values for mobile, Allura C-arm, and AlluraClarity C-arm for noncomplex EVARs were 56±39, 245±142, and 157±120 Gy·cm2 (p<0.001); for complex EVARs, the values were 110±43, 874±653, and 598±319 Gy·cm2 (p<0.001), respectively. On average, KAPfluoro tripled when the mobile C-arm was replaced by the fixed C-arm. There were no significant differences in the KAPfluoro adjusted for the FT between Allura and AlluraClarity (p=0.69). However, there was a major 61% reduction in KAPDSA from 1.36 Gy·cm2 per DSA frame for Allura to 0.54 Gy·cm2 per DSA frame with AlluraClarity (p=0.03). For the mobile C-arm, BMI was not associated with KAP (p=0.13). The associations of BMI with KAPfluoro and KAPDSA were significant for both fixed C-arms but were more robust for Allura compared to AlluraClarity (p=0.02 for KAPfluoro and p<0.001 for KAPDSA). Conclusion: Changing a mobile C-arm for a fixed C-arm in a hybrid operating suite increased the average intraoperative dose during EVAR. Upgrading the Allura fixed C-arm with ClarityIQ technology resulted in a 61% reduction in the radiation per DSA frame.

Publisher

SAGE Publications

Subject

Cardiology and Cardiovascular Medicine,Radiology, Nuclear Medicine and imaging,Surgery

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3