Single Center and Surgeon’s Long-Term (15-19 Years) Patient Satisfaction and Revision Rate of Round Textured Eurosilicone Breast Implants

Author:

Kooiman Laurens1ORCID,Torensma Bart2,Stevens Hieronymus3,van der Lei Berend4

Affiliation:

1. Department of Plastic Surgery, Haaglanden Medical Centre (HMC), The Hague, the Netherlands

2. Department of Anesthesiology and Epidemiology, Leiden University Medical Centre (LUMC), Leiden, the Netherlands

3. Department of Plastic Surgery, Velthuis Clinics, Rotterdam, the Netherlands

4. University of Groningen and University Medical Centre Groningen (UMCG), Groningen, the Netherlands

Abstract

Abstract Background Breast augmentation is one of the most commonly performed aesthetic plastic surgical procedures, with over 250,000 procedures in the United States in 2020 alone. However, the safety of breast implants should be closely researched and monitored, especially in the long term. Objectives This study was undertaken to evaluate the long-term results of round micro-textured Eurosilicone (Eurosilicone S.A.S, Apt Cedex, France) Cristalline Paragel breast implants from a single-center, single-surgeon experience regarding both patient-reported outcome measures and revisions. Methods A retrospective cohort study was undertaken of 84 patients who underwent primary breast augmentation with round micro-textured Eurosilicone Cristalline Paragel breast implants, either submuscular (dual-plane) or subglandular placed, between 2001 and 2004. All patients were contacted for informed consent, and after approval, the validated BREAST-Q questionnaire was sent and utilized to analyze patient satisfaction. In addition, objective data regarding revisions, including capsular contracture, rupture rate, pain, and/or aesthetic causes needing revision surgery, were analyzed. Results High BREAST-Q scores (67%-100% for 0-100 scale variables and 66.0%-77.3% of the patients scored “very satisfied” on categorical variables) were found without clinically significant differences between patients with dual-plane–placed implants and subglandular-placed implants. The overall revision rate was 29.8%, also with no significant differences between groups (P = 0.317). Conclusions This study showed high patient satisfaction and relatively low revision rates after 15 to 19 years of follow-up of round micro-textured Eurosilicone Cristalline Paragel breast implants. No clinically relevant significant differences were found between dual-plane and subglandular placement of the implants. Level of Evidence: 4

Publisher

Oxford University Press (OUP)

Subject

General Medicine,Surgery

Reference29 articles.

1. Five-year safety data for Eurosilicone’s round and anatomical silicone gel breast implants;Duteille;Plast Reconstr Surg Glob Open,2014

2. Ten-year safety data for Eurosilicone’s round and anatomical silicone gel breast implants;Duteille;Aesthet Surg J Open Forum,2019

3. The Dillman total design survey method;Hoddinott;Can Fam Physician,1986

4. Development of a new patient-reported outcome measure for breast surgery: the BREAST-Q;Pusic;Plast Reconstr Surg,2009

Cited by 3 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献