Continuous-Scale Physical Functional Performance Test: Validity, Reliability, and Sensitivity of Data for the Short Version

Author:

Cress M Elaine1,Petrella John K2,Moore Trudy L3,Schenkman Margaret L4

Affiliation:

1. ME Cress, PhD, FACSM, is Associate Professor, Department of Exercise Science and The Gerontology Center, University of Georgia, 300 River Rd, Athens, GA 30602-6554 (USA)

2. JK Petrella, PhD, is Postdoctoral Research Fellow, Geriatric Research, Education Clinical Center, Department of Physiology and Biophysics, University of Alabama–Birmingham, Birmingham, Ala

3. TL Moore, MS, is a graduate assistant and doctoral student in the Department of Exercise Science, University of Georgia

4. ML Schenkman, PT, PhD, is Professor of Physical Therapy, Department of Rehabilitation Medicine, University of Colorado Health Sciences Center, Denver, Colo

Abstract

Abstract Background and Purpose. The Continuous-Scale Physical Functional Performance Test (CS-PFP) can be used to obtain valid, reliable, and sensitive measurements of physical functional capacity. This test requires a fixed laboratory space and approximately 1 hour to administer. This study was carried out in 4 steps, or substudies, to develop and validate a short, community-based version (PFP-10) that requires less space and equipment than the CS-PFP. Subjects and Methods. Retrospective data (n=228) and prospective data (n=91) on men and women performing the CS-PFP or the PFP-10 are reported. A 12-week exercise program was used to examine sensitivity to change. Data analyses were done using paired t-test, Pearson correlation, intraclass correlation coefficient (ICC), and delta index (DI) procedures. Results. The PFP-10 total score and 4 of the 5 domain scores were statistically similar (within 3%) to those of the CS-PFP. The PFP-10 upper-body strength domain score was 17% lower, but was highly correlated (ICC=.97). Community and established laboratory PFP-10 scores were similar (ICC=.85–.97). The PFP-10 also is sensitive to change (DI=.21–.54). Discussion and Conclusion. The PFP-10 yields valid, reliable, and sensitive measurements and can be confidently substituted for the CS-PFP.

Publisher

Oxford University Press (OUP)

Subject

Physical Therapy, Sports Therapy and Rehabilitation

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3