Abstract
Abstract
Purpose
This study aims to investigate the lower extremity loading during activities of daily living (ADLs) using the Continuous Scale of Physical Functional Performance (CS-PFP 10) test and wireless sensor insoles in healthy volunteers.
Methods
In this study, 42 participants were recruited, consisting of 21 healthy older adults (mean age 69.6 ± 4.6 years) and 21 younger healthy adults (mean age 23.6 ± 1.8 years). The performance of the subjects during ADLs was assessed using the CS-PFP 10 test, which comprised 10 tasks. The lower extremity loading was measured using wireless sensor insoles (OpenGo, Moticon, Munich, Germany) during the CS-PFP 10 test, which enabled the measurement of ground reaction forces, including the mean and maximum total forces during the stance phase, expressed in units of body weight (BW).
Results
The total CS-PFP 10 score was significantly lower in older participants compared to the younger group (mean total score of 57.1 ± 9.0 compared to 78.2 ± 5.4, respectively). No significant differences in the mean total forces were found between older and young participants. The highest maximum total forces were observed during the tasks ‘endurance walk’ (young: 1.97 ± 0.34 BW, old: 1.70 ± 0.43 BW) and ‘climbing stairs’ (young: 1.65 ± 0.36 BW, old: 1.52 ± 0.28 BW). Only in the endurance walk, older participants showed a significantly higher maximum total force (p < 0.001).
Conclusion
The use of wireless sensor insoles in a laboratory setting can effectively measure the load on the lower extremities during ADLs. These findings could offer valuable insights for developing tailored recommendations for patients with partial weight-bearing restrictions.
Funder
Schweizerische Gesellschaft für Orthopädie und Traumotologie
University of Bern
Publisher
Springer Science and Business Media LLC
Subject
Critical Care and Intensive Care Medicine,Orthopedics and Sports Medicine,Emergency Medicine,Surgery