Study of the Effect of Different Breast Implant Surfaces on Capsule Formation and Host Inflammatory Response in an Animal Model

Author:

Santanelli di Pompeo FabioORCID,Sorotos MichailORCID,Canese Rossella,Valeri Mauro,Roberto Cirombella,Giorgia Scafetta,Firmani GuidoORCID,di Napoli Arianna

Abstract

Abstract Background Breast implants are biomaterials eliciting a physiological and mandatory foreign body response. Objectives The authors designed an animal study to investigate the impact of different implant surfaces on the formation of the periprosthetic capsule, the inflammatory response, and the cellular composition. Methods The authors implanted 1 scaled-down version of breast implants by different manufactures on 70 female Sprague Dawley rats. Animals were divided into 5 groups of 14 animals. Group A received a smooth implant (Ra ≈ 0.5 µm) according to the ISO 14607-2018 classification, Group B a smooth implant (Ra ≈ 3.2 µm), Group C a smooth implant (Ra ≈ 5 µm), Group D a macrotextured implant (Ra ≈ 62 µm), and Group E a macrotextured implant (Ra ≈ 75 µm). At 60 days, all animals received a magnetic resonance imaging (MRI), and 35 animals were killed and their capsules sent for histology (capsule thickness, inflammatory infiltrate) and immunohistochemistry analysis (cellular characterization). The remaining animals repeated the MRI at 120 days and were killed following the same protocol. Results MRI showed a thinner capsule in the smooth implants (Groups A-C) at 60 days (P < .001) but not at 120 days (P = .039), confirmed with histology both at 60 days (P = .005) and 120 days (P < .001). Smooth implants (Groups A-C) presented a mild inflammatory response at 60 days that was maintained at 120 days and a high M2-Macrophage concentration (anti-inflammatory). Conclusions Our study confirms that smooth implants form a thinner capsule, inferior inflammatory infiltrate, and a cellular composition that indicates a mild host inflammatory response. A new host inflammatory response classification is elaborated classifying breast implants into mild, moderate, and high.

Publisher

Oxford University Press (OUP)

Subject

General Medicine,Surgery

Cited by 12 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3