Thoracic aortic computed tomography angiography in swine: establishment of a baseline for endovascular evaluation of the ascending aorta

Author:

Tao Li1,Xianhao Bao1,Yuxi Zhao1,Ziwen Li2,Ziyi Xu13,Zhaoxiang Zeng1,Mingwei Wu1,Yiming Li1,Ding Xu1,Jiaxuan Feng13,Rui Feng13,Jian Zhou13,Zaiping Jing13

Affiliation:

1. Endovascular Diagnosis and Treatment Center for Heart Valvular Diseases, and Endovascular Diagnosis and Treatment Center for Aortic Dissection, Changhai Hospital, Navy Medical University, Shanghai, China

2. Department of Radiology, Changhai Hospital, Navy Medical University, Shanghai, China

3. Department of Vascular Surgery, Changhai Hospital, Navy Medical University, Shanghai, China

Abstract

AbstractOBJECTIVESOur goal was to establish a baseline of computed tomography (CT) angiographic data for the porcine ascending thoracic aorta for endovascular evaluation of animal experiments and device development.METHODSThoracic aortic CT angiography was conducted on 49 pigs with an average body weight of 60–65 kg. The CT angiographic scans were done on an imaging reconstruction workstation to obtain the specific aortic geometric data, including the diameters of the planes, the heights among the planes and the clock positions of target arteries.RESULTSFourteen important planes were defined in the study for endograft customizing reference. The diameters of the planes were measured, and the heights among the planes were recorded. For endograft fenestrations, the right coronary artery ostium clock position was 100.11 ± 7.29°, and the brachiocephalic trunk ostium clock position was 74.72 ± 6.45°. The best projection angle of the tangent position of the left coronary artery was the right anterior oblique 17 ± 7° position. A pig with a rare congenital giant dilated aorta was found among the candidate experimental animals.CONCLUSIONSFor experimental porcine models, CT angiography has proved to be a suitable imaging technique. The established baseline angiography of the swine can provide reference values for future animal experiments and device development.

Funder

National Natural Science Foundation of China

Publisher

Oxford University Press (OUP)

Subject

Cardiology and Cardiovascular Medicine,Pulmonary and Respiratory Medicine,Surgery

Cited by 5 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3