Atrial and ventricular flows across a transcatheter mitral valve

Author:

Hatoum Hoda1ORCID,Askegaard Gunnar2,Iyer Ramji2,Prasad Dasi Lakshmi3

Affiliation:

1. Department of Biomedical Engineering, Michigan Technological University, Houghton, MI, USA

2. R&D Department, LivaNova PLC, Maple Grove, MN, USA

3. Department of Biomedical Engineering, Georgia Institute of Technology, Atlanta, GA, USA

Abstract

Abstract OBJECTIVES The objective of this study was to evaluate the haemodynamic performance of transcatheter mitral valve replacement (TMVR) Implant with a focus on turbulence and washout adjacent to the ventricular surface of the leaflets. TMVR holds the promise of treating a large spectrum of mitral valve diseases. However, the haemodynamic performance and flow dynamics of such replacements are not fully understood. METHODS A tri-leaflet biopsrosthetic TMVR represented by Caisson implant of size 36A was implanted in the mitral position of a left heart simulator pulse duplicating system under physiological conditions. The 36A implant covers an anterior–posterior range of 26–32 mm and a commissure-to-commissure range of 30–36 mm. Transmitral pressure gradient, effective orifice area and regurgitant fraction were calculated. Particle image velocimetry was performed to evaluate turbulence in 2 perpendicular planes (Reynolds and viscous shear stresses, respectively). Additionally, dye experiments were performed to visualize washout. RESULTS Transmitral pressure gradient was 1.29 ± 0.27 mmHg and effective orifice area was 2.96 ± 0.28 cm2. Regurgitant fraction was 14.13 ± 0.08%. Total washout was 4.27 cardiac cycles. Largest viscous shear stress reaches 3.7 Pa and 2.4 Pa in ventricle and atrium, respectively. Reynolds shear stress in the atrial side was <10 Pa. In the ventricular side, the largest Reynolds shear stress reached ∼35 Pa. CONCLUSIONS TMVR leads to favourable haemodynamics with low degree of turbulence combined with fast washout around the leaflets indicating promising potential for freedom from blood damage potential and thrombosis corroborated by initial clinical studies as part of the valves’s Early Feasibility Study.

Funder

LivaNova

Publisher

Oxford University Press (OUP)

Subject

Cardiology and Cardiovascular Medicine,Pulmonary and Respiratory Medicine,Surgery

Cited by 3 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3