Mid-term durability of polytetrafluoroethylene patches in unicuspid aortic valve repair

Author:

Karliova Irem1ORCID,Ehrlich Tristan1,Matsushima Shunsuke1ORCID,Ewen Sebastian2,Schäfers Hans-Joachim1ORCID

Affiliation:

1. Department of Thoracic and Cardiovascular Surgery, Saarland University Medical Center, Homburg/Saar, Germany

2. Department of Cardiology, Saarland University Medical Center, Homburg/Saar, Germany

Abstract

Abstract OBJECTIVES Unicuspid aortic valve (UAV) morphology is a cause for aortic valve dysfunction in childhood or adolescence. Repair requires the use of patch material, and polytetrafluoroethylene (PTFE) has been proposed for this purpose because of lack of calcification. We reviewed our mid-term experience with PTFE for the repair of UAV to analyse the durability of this technique. METHODS Out of 21 patients with an UAV undergoing aortic valve repair for severe aortic regurgitation between 2014 and 2016, 11 patients (52%) were treated using PTFE patch material. Aortic regurgitation was present in all patients, the primary indication for surgery was regurgitation in 8, stenosis in 2 and aneurysm in 1. Symmetric bicuspidization of the UAV was performed in all. One patient required additional root remodelling for root dilatation, and another 3 tubular ascending aortic replacement. RESULTS No patient died in hospital or during follow-up. Seven patients (63.6%) required reoperation for progressive AR. Freedom from reoperation was 58% at 1 and 35% at 5 years postoperatively. At reoperation the PTFE patches were found dehisced from aortic wall and/or native cusp tissue. In 3 patients re-repair was performed; a stable result was achieved in 1. Two patients underwent valve replacement 3 months and 1 year postoperatively. The other 4 patients underwent valve replacement. CONCLUSIONS The repair of UAVs using PTFE patch is associated with poor durability, a more durable patch with better healing characteristics material is needed.

Publisher

Oxford University Press (OUP)

Subject

Cardiology and Cardiovascular Medicine,Pulmonary and Respiratory Medicine,Surgery

Cited by 5 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

1. Mid-term performance of decellularized equine pericardium in congenital heart surgery;Interactive CardioVascular and Thoracic Surgery;2022-11-07

2. Symmetric repair of the unicuspid aortic valve;European Journal of Cardio-Thoracic Surgery;2022-07-25

3. Bicuspidization of a unicuspid valve using sliding plasty of a rudimentary right coronary cusp;European Journal of Cardio-Thoracic Surgery;2022-06-29

4. Reparación valvular aórtica con técnica de Yacoub en pacientes con cardiopatías congénitas;Cirugía Cardiovascular;2022-05

5. Which Aortic Valve Can Be Surgically Reconstructed?;Current Cardiology Reports;2021-07-02

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3