Mid-term performance of decellularized equine pericardium in congenital heart surgery

Author:

Weixler Viktoria H M12,Kuschnerus Kira1,Romanchenko Olga1,Ovroutski Stanislav3,Cho Mi-Young1,Berger Felix23,Sigler Matthias4,Sinzobahamvya Nicodème1,Photiadis Joachim1,Murin Peter1

Affiliation:

1. German Heart Center Berlin Department of Congenital Heart Surgery - Pediatric Heart Surgery, , Berlin, Germany

2. DZHK (German Centre for Cardiovascular Research) , partner site Berlin, Germany

3. German Heart Center Berlin Department of Congenital Heart Disease - Pediatric Cardiology, , Berlin, Germany

4. Georg-August University Göttingen Department of Pediatric Cardiology and Intensive Care Medicine, , Göttingen, Germany

Abstract

Abstract Objective The aim was to report mid-term performance of decellularized equine pericardium used for repair of various congenital heart defects in the pediatric population. Methods A retrospective review of all patients undergoing patch implantation between 2016 – 2020 was performed. Patch quality, surgical handling, hemostasis and early patch-related complications were studied on all patients. Mid-term performance was observed in patients with ≥12 months follow-up and intact patch at discharge (without reoperation/stent implantation). Results A total of 201 patients with median age of 2.5 years [interquartile range (IQR): 0.6-6.5] underwent 207 procedures at 314 implant locations. The patch was used in following numbers/locations: 171 for pulmonary artery (PA) augmentation, 36 for aortic repair, 35 for septal defect closure, 22 for valvular repair and 50 at other locations. Early/30-day mortality was 6.5%. Early patch-related reoperations/stent implantations occurred in 28 locations (8.9%). No patch-related complications were noted except for bleeding from implant site in three locations (1%). Follow-up ≥ 12 months was available for 132 patients/200 locations. During a median follow-up of 29.7 months [IQR: 20.7-38.3], 53 patch-related reoperations/catheter reinterventions occurred (26.5%) with the majority in PA position (88.7%, 47/53). Overall 12- and 24-months freedom from patch-related reoperation/catheter reintervention per location was 91.5% (95% CI: 86.7%-94.6%) and 85.2% (95% CI: 78.9%-89.6%) respectively. Conclusion Decellularized equine pericardium used for repair of various congenital heart defects showed acceptable mid-term performance. Reoperation/reintervention rates were in a range as observed with other xenogeneic materials previously reported articles, occurring most frequently after PA augmentation.

Publisher

Oxford University Press (OUP)

Subject

Cardiology and Cardiovascular Medicine,Pulmonary and Respiratory Medicine,Surgery

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

1. Commentary: the ideal patch material for congenital cardiac surgery: one ring to rule them all?;Interdisciplinary CardioVascular and Thoracic Surgery;2023-02-08

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3