Isolated subcutaneous implantable cardioverter-defibrillator generator displacement causing inappropriate shocks despite preserved lead tip and coil position: a case report

Author:

Chow Ji-Jian1ORCID,Bilham James2,Lane Rebecca2

Affiliation:

1. Hammersmith Hospital , London W12 0NN, UK

2. Cardiology Department, Harefield Hospital , Uxbridge UB9 6JH, UK

Abstract

AbstractBackgroundSubcutaneous implantable cardioverter-defibrillators (S-ICDs) are increasingly used in patients without a pacing indication, and may reduce venous complications, endocarditis and extraction morbidity. Subcutaneous implantable cardioverter-defibrillator displacements may be less obvious than their transvenous counterparts.Case summaryA 59-year-old man was found to have dilated cardiomyopathy associated with heavy alcohol intake following investigation for a stroke. Despite 2 years of alcohol cessation and optimal drug therapy, his ejection fraction remained severely impaired, and he received an S-ICD using the manufacturer recommended screening and implant method, and by an experienced operator. Ten months later, inappropriate shocks were delivered despite optimal programming. Device displacement was demonstrated by lateral chest radiography on the second instance of inappropriate therapy. On the first admission, a lateral film was not performed, and simple device programming was undertaken which failed to prevent the second occurrence. The patient requested an explant; as ventricular function had improved following initiation of sacubutril/valsartan, the clinical team opted to remove the device.DiscussionCareful inspection of lateral chest films and review of device indication are needed to reduce the risk of inappropriate shocks. This is the first description of inappropriate device activity following lone generator displacement—lead displacement is well described.

Publisher

Oxford University Press (OUP)

Subject

Cardiology and Cardiovascular Medicine

Reference6 articles.

1. The entirely subcutaneous defibrillator (S-ICD): state of the art and selection of the ideal candidate;De Maria;Curr Cardiol Rev,2015

2. Inappropriate shocks in the subcutaneous ICD: incidence, predictors and management;Nordkamp LR;Int J Cardiol,2015

3. Inappropriate shocks in single-chamber and subcutaneous implantable cardioverter-defibrillators: a systematic review and meta-analysis;Auricchio;Europace,2017

4. Implantation of the subcutaneous implantable cardioverter-defibrillator;Brouwer;Circ Arrhythm Electrophysiol,2017

5. Twiddler’s syndrome with a subcutaneous implantable cardioverter-defibrillator presenting with an inappropriate shock: a case report;Camm;Eur Heart J Case Rep,2019

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3