Implantation of the Subcutaneous Implantable Cardioverter-Defibrillator

Author:

Brouwer Tom F.1,Miller Marc A.1,Quast Anne-Floor B.E.1,Palaniswamy Chandrasekar1,Dukkipati Srinivas R.1,Reddy Vivek1,Wilde Arthur A.1,Willner Jonathan M.1,Knops Reinoud E.1

Affiliation:

1. From the Department of Clinical & Experimental Cardiology, Heart Center, Amsterdam Medical Center, University of Amsterdam, Noord-Holland, The Netherlands (T.F.B., A.-F.B.E.Q., A.A.W., R.E.K.); and Helmsley Cardiac Arrhythmia Service, Icahn School of Medicine at Mount Sinai, New York, NY (M.A.M., C.P., S.R.D., V.R., J.M.W.).

Abstract

Background— Alternative techniques to the traditional 3-incision subcutaneous implantation of the subcutaneous implantable cardioverter-defibrillator may offer procedural and cosmetic advantages. We evaluate 4 different implant techniques of the subcutaneous implantable cardioverter-defibrillator. Methods and Results— Patients implanted with subcutaneous implantable cardioverter-defibrillators from 2 hospitals between 2009 and 2016 were included. Four implantation techniques were used depending on physician preference and patient characteristics. The 2- and 3-incision techniques both place the pulse generator subcutaneously, but the 2-incision technique omits the superior parasternal incision for lead positioning. Submuscular implantation places the pulse generator underneath the serratus anterior muscle and subfascial implantation underneath the fascial layer on the anterior side of the serratus anterior muscle. Reported outcomes include perioperative parameters, defibrillation testing, and clinical follow-up. A total of 246 patients were included with a median age of 47 years and 37% female. Fifty-four patients were implanted with the 3-incision technique, 118 with the 2-incision technique, 38 with submuscular, and 37 with subfascial. Defibrillation test efficacy and shock lead impedance during testing did not differ among the groups; respectively, P =0.46 and P =0.18. The 2-incision technique resulted in the shortest procedure duration and time-to-hospital discharge compared with the other techniques ( P <0.001). A total of 18 complications occurred, but there were no significant differences between the groups ( P =0.21). All infections occurred in subcutaneous implants (3-incision, n=3; 2-incision, n=4). In the 2-incision group, there were no lead displacements. Conclusions— The presented implantation techniques are feasible alternatives to the standard 3-incision subcutaneous implantation, and the 2-incision technique resulted in shortest procedure duration.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Physiology (medical),Cardiology and Cardiovascular Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3