Headgear compliance as assessed by a temperature-sensitive recording device: a prospective clinical study

Author:

Huanca Ghislanzoni Luis1,Ameur Sofian1,Antonarakis Gregory S1,Kiliaridis Stavros1

Affiliation:

1. Department of Orthodontics, University of Geneva, Geneva, Switzerland

Abstract

Summary Objective To accurately describe compliance in headgear wearing time by using a temperature- and force-sensitive device over an 8 month period of use in a prospective clinical manner. Materials and methods Twenty children with Class II malocclusion aged 8–12 years were randomly selected for treatment with cervical headgear. The headgears were equipped with an electronic module, which measured temperature and force, and patients were instructed to wear the headgear 12 hours daily. The recorded values were analysed to determine the number of days the headgear was used, the number of hours per day it was worn, and the percentage of compliance (100 per cent corresponding to 12 hours daily). Results The average treatment period was 8.4 months with 5.8 months of effective use. When effectively used, headgear was worn 8.7 hours a day (compliance of 73 per cent). Including days where it was not worn, compliance was 6.4 hours (54 per cent). The appliance was used on average 0.5 hours during the day (8 am–8 pm) and 5.9 hours during the night (8 pm–8 am). Very low compliance was recorded during July and August. Conclusion The average compliance with cervical headgear use was 54 per cent of the 12 hour prescription. The headgear was effectively used only 5.8 months over the study period, with roughly 30 per cent of no use. Headgear was used almost exclusively during evening and night-time. During the summer period, compliance was particularly poor.

Publisher

Oxford University Press (OUP)

Subject

Orthodontics

Reference21 articles.

1. Current trends in headgear use for the treatment of Class II malocclusions;Tüfekçi;The Angle Orthodontist,,2016

2. The timing headgear;Northcutt;Journal of Clinical Orthodontics,,1974

3. An investigation into the reliability of the timing headgear;Banks;British Journal of Orthodontics,,1987

4. Clinical and quantitative assessment of headgear compliance: a pilot study;Brandão;American Journal of Orthodontics and Dentofacial Orthopedics,,2006

5. Comparing subjective and objective measures of headgear compliance;Bos;American Journal of Orthodontics and Dentofacial Orthopedics,,2007

Cited by 10 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3