TO USE OR NOT USE PATIENT SHIELDING ON PREGNANT WOMEN UNDERGOING CT PULMONARY ANGIOGRAPHY: A PHANTOM STUDY

Author:

Begano Dino1,Söderberg Marcus23ORCID,Bolejko Anetta14ORCID

Affiliation:

1. Department of Medical Imaging and Physiology, Skåne University Hospital, Malmö SE-205 02, Sweden

2. Medical Radiation Physics, Department of Translational Medicine, Lund University, Malmö SE-205 02, Sweden

3. Radiation Physics, Department of Hematology, Oncology and Radiation Physics, Skåne University Hospital, Malmö SE-205 02, Sweden

4. Department of Health Sciences, Lund University, Lund SE-221 00, Sweden

Abstract

Abstract Pregnancy increases the risk of pulmonary embolism. Computed tomography pulmonary angiography (CTPA) is used for diagnosis. CT generates ionising radiation, and thus, abdominal shielding may be used. This phantom study investigated the effects of patient shielding and scan length reduction on the fetal and maternal ionising radiation dose from CTPA. The absorbed dose to the fetus was measured using thermoluminescent dosemeters. Estimated effective doses to the pregnant patient were based on the dose-length products. Shielding increased both the effective dose to the patient by 47% and the mean absorbed dose to the fetus (0.10 vs. 0.12 mGy; p < 0.001) compared with unshielded standard CTPA, as it affected the automatic exposure control. Shielded short CTPA marginally lowered only the mean fetal absorbed dose (0.03 vs. 0.02 mGy; p = 0.018). Shortening the scan reduced the fetal absorbed dose most effectively by 70% (0.10 vs. 0.03 mGy; p = 0.006), compared with the standard unshielded scan. Shielding modestly reduces fetal radiation dose but may compromise automatic exposure control, possibly increasing the maternal and fetal radiation dose. Shortening the scan is beneficial, assuming anatomical coverage is secured.

Funder

Department of Medical Imaging and Physiology

Publisher

Oxford University Press (OUP)

Subject

Public Health, Environmental and Occupational Health,Radiology, Nuclear Medicine and imaging,General Medicine,Radiation,Radiological and Ultrasound Technology

Reference28 articles.

1. Pulmonary embolism in pregnancy;Bourjeily;Lancet,2010

2. Imaging in pregnant patients: Examination appropriateness;Wieseler;Radiographics,2010

3. ICRP publication 84—pregnancy and medical radiation;International Commission of Radiological Protection;Ann. ICRP,2000

4. Pulmonary embolism in pregnancy: CT pulmonary angiography versus perfusion scanning;Shahir;AJR,2010

5. Imaging of acute pulmonary embolism: an update;Alastair;Cardiovasc. Diag. Ther.,2018

Cited by 20 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3