OPTIMISATION OF PATIENT DOSE AND IMAGE QUALITY IN FLUOROSCOPICALLY GUIDED CERVICAL SPINE SURGERY: A PHANTOM-BASED STUDY

Author:

Metaxas Vasileios I1,Messaris Gerasimos A1,Gatzounis George D2,Panayiotakis George S1

Affiliation:

1. Department of Medical Physics, School of Medicine, University of Patras, Patras, Greece

2. Department of Neurosurgery, School of Medicine, University of Patras, Patras, Greece

Abstract

Abstract The purpose of the current study was to provide useful data, which may help neurosurgeons to manage the patient dose and image quality in spinal surgery procedures, utilising a phantom and a test object. The kerma area product, cumulative dose (CD) and entrance surface dose (ESD) rate on the phantom and image intensifier were measured, for selectable fields of view (FOVs), fluoroscopy modes, two geometric magnifications and various phantom thicknesses. The images were subjectively evaluated regarding low-contrast detectability and high-contrast resolution. Signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), high-contrast spatial resolution (HCSR) and figure of merit (FOM) values were also estimated. The ESD rates increased with increasing phantom thickness, when using electronic or geometric magnification, continuous or high-definition fluoroscopy (HDF). The observers’ evaluation showed relatively slight changes in image quality when pulsed fluoroscopy was used. SNR, CNR and HCSR values decreased with increasing phantom thicknesses, while remained almost constant when using pulsed fluoroscopy. SNR and HCSR improved in HDF, while the CNR remained almost constant only for the FOVs 23 and 17 cm. By applying electronic magnification, this resulted in improved HCSR. FOM values decreased in HDF, with increasing phantom thickness and using electronic magnification. For the ‘thinnest’ patients, CD may overestimate skin dose by 25% than the actual values. Geometric magnification resulted in improved FOM, especially for low-dose fluoroscopy and FOV 23 cm. The knowledge of the increments in dose values, image quality and FOM indices concerning phantom thickness may help neurosurgeons to optimise spinal surgery procedures by selecting the appropriate operational parameters, which could contribute toward the establishment of a radiation protection culture.

Publisher

Oxford University Press (OUP)

Subject

Public Health, Environmental and Occupational Health,Radiology Nuclear Medicine and imaging,General Medicine,Radiation,Radiological and Ultrasound Technology

Reference42 articles.

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3