PATIENT SIZE INDICES AND DOSE IN FLUOROSCOPICALLY GUIDED LUMBAR DISCECTOMY AND FUSION: A PRELIMINARY STUDY

Author:

Metaxas Vasileios I1,Gatzounis George D23,Tzortzidis Fotios N3,Panayiotakis George S14

Affiliation:

1. Department of Medical Physics, School of Medicine, University of Patras, University Campus, 26504 Rio Achaia, Greece

2. Department of Neurosurgery, School of Medicine, University of Patras, University Campus, 26504 Rio Achaia, Greece

3. Department of Neurosurgery, University Hospital of Patras, 265 04 Rio Achaia, Greece

4. Department of Medical Physics, University Hospital of Patras, 26504 Rio Achaia, Greece

Abstract

Abstract Patient dose values varied significantly during interventional procedures, mainly due to the patient size, operators’ choices and clinical complexity. In this study, the effect of applying a previously described and validated size-correction method to normalise kerma-area product (KAP) and average KAP rate values of the whole procedure (KAP rate) and isolate variations in dose due to the patient size and complexity, during lumbar discectomy and fusion (LDF) procedures, was investigated. Fluoroscopy time (FT), KAP, KAP rate and patient size data (weight, height and equivalent diameter) were recorded, for 96 patients who underwent single or multilevel LDF procedures by three senior neurosurgeons, defining three different patient groups (surgeon 1, surgeon 2, surgeon 3). Simple linear regression and coefficients of determination were used to investigate the relationship between uncorrected and corrected KAP and KAP rate values and patient size indices in these groups. The results showed that the size correction decreased the influence of patient size and could contribute to the isolation of the variations in patient dose due to the patient size. From this point of view, dose surveys during lumbar spine interventions may include dosimetric data from all patients independently of their body size and not only for standard-sized patients, providing the advantage of accessible data collection for the establishment of local dose reference levels and optimisation purposes, within the framework of the radiation protection program in the Neurosurgery Department.

Publisher

Oxford University Press (OUP)

Subject

Public Health, Environmental and Occupational Health,Radiology Nuclear Medicine and imaging,General Medicine,Radiation,Radiological and Ultrasound Technology

Reference26 articles.

1. Radiological protection in fluoroscopically guided procedures performed outside the imaging department;International Commission on Radiological Protection;Ann. ICRP,2010

2. Lumbar underbody fusion: techniques, indications and comparison of underbody fusion options including PLIF, TLIF, MI-TLIF, OLIF/ATP, LLIF and ALIF;Mobs;J. Spine Surg.,2015

3. Surgeon and patient radiation exposure in minimally invasive transforaminal lumbar interbody fusion;Bindal;J. Neurosurg. Spine,2008

4. Occupational health hazards in the interventional laboratory: Time for a safer environment. Catheter Cardiovasc;Klein;Inter. Des.,2018

5. Radiation exposure to the surgeon during minimally invasive spine procedures is directly estimated by patient dose;Harrison Farber;Eur. Spine J.,2018

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3