ABSTRACT The aim of this study was to determine the additional value of the false-profile (FP) view radiograph in the diagnosis of developmental dysplasia of the hip (DDH), as compared with an anteroposterior (AP) pelvic radiograph only, and evaluate the correlation between the Wiberg-lateral center edge angle (W-LCEA) and Wiberg-anterior center edge angle (W-ACEA). We used baseline data from a nationwide prospective cohort study (Cohort Hip and Cohort Knee). DDH was quantified on AP pelvic and FP hip radiographs using semi-automatic measurements of the W-LCEA and W-ACEA. A threshold of <20° was used to determine DDH for both the W-LCEA and the W-ACEA. The proportion of DDH only present on the FP view determined the FP view additional value. The correlation between the W-LCEA and W-ACEA was determined. In total 720 participants (1391 hips) were included. DDH was present in 74 hips (5.3%), of which 32 were only present on the FP view radiograph (43.2%). The Pearson correlation coefficient between W-LCEA and W-ACEA of all included hips was 0.547 (95% confidence interval: 0.503–0.591) and 0.441 (95% confidence interval: 0.231–0.652) in hips with DDH. A mean difference of 9.4° (SD 8.09) was present between the W-LCEA and the W-ACEA in the hips with DDH. There is a strong additional value of the FP radiograph in the diagnosis of DDH. Over 4 out of 10 (43.2%) individuals’ DDH will be missed when only using the AP radiograph. In hips with DDH a moderate correlation between W-LCEA and W-ACEA was calculated indicating that joints with normal acetabular coverage on the AP view can still be undercovered on the FP view.

Funder

Dutch Arthritis Society

Publisher

Oxford University Press (OUP)

Subject

General Earth and Planetary Sciences,General Environmental Science

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3