Reliability of Hip Strength Assessment in Young Active People with Hip Dysplasia: An Examination in Student Circus Artists

Author:

Ganderton C,O’Brien MJM,Han J,Wallis AK,Munro D,O'Shea T,Grabinski R,King MG

Abstract

BACKGROUND: Developmental dysplasia of the hip (DDH) is common in performing artists and other young active individuals and involves abnormalities in bony morphology of the acetabulum and proximal femur that can negatively impact walking biomechanics, muscular strength, quality of life, and sleep. Rehabilitation for hip-related conditions should target known modifiable impairments such as hip muscle strength, though a reliable method of assessment in this population remains unclear. OBJECTIVE: To determine the inter- and intra-rater reliability of hip muscle strength assessments using handheld dynamometry (HHD) in young active circus artists with DDH. METHODS: Reliability of hip strength in all planes was assessed using HHD in 21 adult performing circus arts students (mean age 21.3 yrs [3.2]; 13 M, 5 F, 3 NB) with symptomatic radiologically and clinically diagnosed hip dysplasia. The reliability of average peak force and absolute peak force were expressed for each position tested. Reliability was assessed using intraclass correlation coefficients (ICC) with standard error of measurement (SEM) and minimal detectable change (MDC) values calculated to improve clinical interpretability. RESULTS: Good to excellent inter-rater reliability resulted for all hip muscle strength testing positions, ICC=0.88 (95%CI 0.70 to 0.95) to ICC=0.97 (0.92 to 0.99), except average peak hip flexion strength, ICC=0.71 (0.28 to 0.88). Absolute peak hip abduction, ICC=0.77 (0.16 to 0.94), and adduction strength, ICC=0.72 (–0.55 to 0.92), demonstrated the lowest intra-rater reliability. Transverse plane strength measures (rotation) produced the lowest SEM and MDC values followed by the frontal plane (abduction/adduction) and sagittal plane (flexion/extension). CONCLUSION: HHD is an appropriate and reliable method to assess hip muscle strength in circus artists with DDH.

Publisher

Science and Medicine, Inc.

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3