Comparison of sensitivity characteristics between GAFCHROMIC LD-V1 and GAFCHROMIC XR-QA2 in mammographic dosimetry

Author:

Gotanda Tatsuhiro12ORCID,Kawaji Yasuyuki34,Yatake Hidetoshi5,Imai Shinya67,Akagawa Takuya8,Gotanda Rumi12,Katsuda Toshizo9ORCID

Affiliation:

1. Department of Radiological Technology , Faculty of Health Science and Technology, , Okayama 701-0193 , Japan

2. Kawasaki University of Medical Welfare , Faculty of Health Science and Technology, , Okayama 701-0193 , Japan

3. Department of Radiological Science , Faculty of Health Science, , Fukuoka 815-8510 , Japan

4. Junshin Gakuen University , Faculty of Health Science, , Fukuoka 815-8510 , Japan

5. Department of Breast Cancer Center, Kaizuka City Hospital , Osaka 597-0015 , Japan

6. Department of Radiological Science , Faculty of Health Science, , Osaka 559-8611 , Japan

7. Morinomiya University of Medical Sciences , Faculty of Health Science, , Osaka 559-8611 , Japan

8. Department of Radiological Technology, Tokushima Red Cross Hospital , Tokushima 773-0001 , Japan

9. Medical Radiation Technology, Shizuoka College of Medical Care Science , Hamamatsu 434-0041 , Japan

Abstract

Abstract In recent years, radiochromic films have begun to be used for dosimetry in mammography; however, the most sensitive GAFCHROMIC XR-QA2 (XR-QA2) film is no longer available owing to its discontinuation. In this study, we evaluated the sensitivity characteristics of GAFCHROMIC LD-V1 (LD-V1) as an alternative to XR-QA2 in the field of mammography, at a low dose and low energy. Our results show that the average ratio of the concentration change of LD-V1 divided by the concentration change of XR-QA2 at each absorbed dose was 53.7%, indicating the sensitivity of LD-V1 to be approximately half of XR-QA2. In addition, the linearity of the concentration change is sufficient even within a dose range of 0.59–14.52 mGy, which is lower than the manufacturer's recommended dose range. Therefore, the LD-V1 is capable of accurate dose assessment even with a low dose and the low level of energy used in mammography.

Funder

Kawasaki University of Medical Welfare Scientific Research Fund

Publisher

Oxford University Press (OUP)

Subject

Public Health, Environmental and Occupational Health,Radiology, Nuclear Medicine and imaging,General Medicine,Radiation,Radiological and Ultrasound Technology

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

1. Characterization of a new low‐dose and low‐energy Gafchromic film LD‐V1;Journal of Applied Clinical Medical Physics;2024-09-11

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3