Affiliation:
1. Stomatology Department, University of Valencia, Spain
Abstract
Summary
Background/objective
Patient compliance during orthodontic treatment is one of the factors that most affects success in the final result. The use of removable appliances is frequent at an early age and the monitoring of its use is essential to assess the collaboration of the patient. The aim of this study was to establish the effectiveness of microsensors included in removable appliances during orthodontic treatment or in the retention phase to enable a reliable and individualized follow-up of the patient.
Search methods
The article search was carried out in various electronic databases and journals without any language restrictions.
Selection criteria
Studies using microsensors into removable appliances were selected with the key selection criterion of a minimum follow-up of 4 weeks.
Data collection and analysis
The quality of the studies included was evaluated using the Cochrane scale for the randomized controlled trials and the Newcastle Ottawa Scale for control–case, cohort, and transversal studies. The mean of the differences with a 95% confidence interval was expressed for the continuous data.
Results
Twenty-nine full-text articles were analysed and included in the qualitative synthesis. In general, the mean daily wear time of removable appliances measured objectively was less than the time that the professional had predetermined.
Conclusions
The use of microsensors as an objective measurement method enhances communication and boosts confidence in the orthodontist–patient relationship. More random clinical studies with temperature sensors are needed to establish to what extent they influence the orthodontic outcome.
Registration
PROSPERO (CRD42019120525).
Publisher
Oxford University Press (OUP)
Reference40 articles.
1. Cooperation of adolescents in orthodontic treatment;Albino;Journal of Behavioral Medicine,1991
2. Relationship between patient discomfort, appliance acceptance and compliance in orthodontic therapy;Doll;Journal of Orofacial Orthopedics,2000
3. Key issues and suggestions for patient compliance assessment: sources of information, focus of measures, and nature of response options;Hays;Journal of Compliance in Health Care,1987
4. Microsensor technology to help monitor removable appliance wear;Ackerman;American Journal of Orthodontics and Dentofacial Orthopedics,2009
5. A microsensor for monitoring removable-appliance wear;Schott;Journal of Clinical Orthodontics,2011
Cited by
8 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献