Diagnostic evaluation of serum (1, 3)-β-d-glucan levels using the Fungitec G-Test MK kit for Pneumocystis jirovecii pneumonia (PCP) in non-HIV patients

Author:

Ideguchi Shuhei12,Yamamoto Kazuko234,Hirayama Tatsuro2,Takazono Takahiro2ORCID,Imamura Yoshifumi2,Miyazaki Taiga2,Sakamoto Noriho2,Izumikawa Koichi3,Yanagihara Katsunori5,Morimoto Shimpei6,Mukae Hiroshi12

Affiliation:

1. Department of Respiratory Medicine, Nagasaki University Graduate School of Biomedical Sciences, Nagasaki, Japan

2. Department of Respiratory Medicine, Nagasaki University Hospital, Nagasaki, Japan

3. Department of Infection Control and Education Center, Nagasaki University Hospital, Nagasaki, Japan

4. Clinical Research Center, National Organization Hospital, Nagasaki Medical Center, Omura, Japan

5. Department of Laboratory Medicine, Nagasaki University Hospital, Nagasaki, Japan

6. Innovation Platform & Office for Precision Medicine, Nagasaki University Graduate School of Biomedical Sciences, Nagasaki, Japan

Abstract

Abstract Pneumocystis jirovecii pneumonia (PCP) is an opportunistic and life-threatening pulmonary infection with an increasing prevalence among individuals who are human immunodeficiency virus (HIV)-negative. Evidence regarding diagnostic testing of PCP in this patient population is insufficient. We evaluated the performance of serum (1, 3)-β-d-glucan (BDG) using the Fungitec G-test MK kit for diagnosing PCP in non-HIV patients. We retrospectively analyzed data from 219 non-HIV adult patients who underwent bronchoscopy and were tested for P. jirovecii DNA by PCR using lavage samples from the lower respiratory tract. Fifty PCP patients and 125 non-PCP patients were included. The most common underlying diseases were malignancies and systemic autoimmune diseases. Using the serum BDG Fungitec G-test MK test to diagnose PCP, the area under the receiver operating characteristic curve (AUC) was 0.924, whereas the modified cut-off value of 36.6 pg/mL had a sensitivity and specificity of 92.0% and 84.8%, respectively. The AUC for patients with systemic autoimmune diseases was 0.873, and the accuracy of serum BDG test declined when using methotrexate (MTX). In conclusion, the serum BDG test was useful for diagnosing PCP in non-HIV patients; however, the results should be carefully interpreted in case of MTX administration. Lay Summary The Fungitec G-test MK kit for measuring serum (1, 3)-β-d-glucan (BDG) levels had a sufficient diagnostic performance for Pneumocystis jirovecii pneumonia (PCP) in human immunodeficiency virus-negative patients. However, the results should be carefully interpreted in case of MTX administration.

Publisher

Oxford University Press (OUP)

Subject

Infectious Diseases,General Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3