Author:
Taniguchi Jumpei,Nakashima Kei,Matsui Hiroki,Watari Tomohisa,Otsuki Ayumu,Ito Hiroyuki,Otsuka Yoshihito
Abstract
Abstract
Background
Non-human immunodeficiency virus (HIV) Pneumocystis pneumonia (PCP) is a fulminant disease with an increasing incidence. The serum beta-d-glucan (BDG) assay is used as an adjunct to the diagnosis of PCP; however, the cut-off value for this assay is not well-defined, especially in the non-HIV PCP population. Therefore, we aimed to identify the assay cut-off value for this population.
Methods
In this retrospective observational study, we reviewed the medical records of all patients (≥ 18 years old) with clinical suspicion of PCP who underwent evaluation of respiratory tract specimens between December 2008 and June 2014 at Kameda Medical Center. We created a receiver operating characteristic curve and calculated the area under the curve to determine the cut-off value for evaluating the inspection accuracy of the BDG assay.
Results
A total of 173 patients were included in the study. Fifty patients showed positive results in specimen staining, loop-mediated isothermal amplification assay, and polymerase chain reaction test, while 123 patients showed negative results. The receiver operating characteristic analyses suggested that the BDG cut-off level was 8.5 pg/mL, with a sensitivity and specificity of 76% and 76%, respectively.
Conclusions
The Wako-BDG cut-off value for the diagnosis of non-HIV PCP is 8.5 pg/mL, which is lower than the classical cut-off value from previous studies. Clinicians should potentially consider this lower BDG cut-off value in the diagnosis and management of patients with non-HIV PCP.
Trial registration: The participants were retrospectively registered.
Publisher
Springer Science and Business Media LLC