An Interlaboratory-Verified Method for the Determination of Vitamins Aand E inMilk- and Soy-Based Infant Formula by Liquid Chromatography with Matrix Solid-Phase Dispersion Extraction

Author:

Chase G William1,Ye Lin2,Stoakes Vicky C3,Eitenmiller Ronald R4,Long Austin R3

Affiliation:

1. U.S. Food and Drug Administration, Atlanta Center for Nutrient Analysis, 60 Eighth St, Atlanta, GA 30602

2. University of Georgia, Department of Food Science and Technology, Athens, GA 30309

3. U.S. Food and Drug Administration, Atlanta Center for Nutrient Analysis, 60 Eighth St, Atlanta, GA 30309

4. University of Georgia, Department of Food Science and Technology, Athens, GA 30602

Abstract

Abstract An interlaboratory-verified, liquid chromatographic (LC) method is presented for determination of all-racemic α-tocopheryl acetate and retinyl palmitate in infant formula. The extraction procedure uses matrix solid-phase dispersion. A sample is mixed with C18, and the mixture is packed into a reservoir and eluted with selective solvents to extract the analytes. After evaporation and filtration, the sample extract is injected directly into a normal-phase LC system with fluorescence detection. All-racemic α-tocopheryl acetate and retinyl palmitate are quantitated isocratically with a mobile phase of hexane containing isopropanol at 0.2% (v/v) and 0.125% (v/v), respectively. A nonfortified zero control reference material (ZRM) was spiked at 5 levels, with 5 replicate analyses of 1/2x, x, 2x, 4x, and 16x where “x” represents the minimum levels of 250 IU/100 kcal (vitamin A) and 0.7 IU/100 kcal (vitamin E) as specified in Title 21 of the Code of Federal Regulations, part 107.100. Recoveries of retinyl palmitate ranged from 83.8 to 107%, and those of all-racemic α-tocopheryl acetate ranged from 87.7 to 108%. Two additional laboratories analyzed the ZRM samples at 4 spiking levels with 6 replicates. Recoveries of retinyl palmitate and all-racemic α-tocopheryl acetate ranged from 92.2 to 104% and from 91.7 to 101%, respectively, in the second laboratory. Recoveries of retinyl palmitate and all-racemic α-tocopheryl acetate ranged from 85.3 to 97.0% and from 86.6 to 110%, respectively, in the third laboratory. Relative standard deviations for all 3 laboratories ranged from 0.2 to 7.5% with an average of 2.9%. In addition, each laboratory analyzed a commercial milk- and commercial soy-based infant formula. Excellent agreement in results was obtained between the 3 laboratories for vitamins A and E in all matrixes.

Publisher

Oxford University Press (OUP)

Subject

Pharmacology,Agronomy and Crop Science,Environmental Chemistry,Food Science,Analytical Chemistry