Continuous and high-precision atmospheric concentration measurements of COS, CO<sub>2</sub>, CO and H<sub>2</sub>O using a quantum cascade laser spectrometer (QCLS)

Author:

Kooijmans Linda M. J.ORCID,Uitslag Nelly A. M.,Zahniser Mark S.,Nelson David D.,Montzka Stephen A.ORCID,Chen HuilinORCID

Abstract

Abstract. Carbonyl sulfide (COS) has been suggested as a useful tracer for gross primary production as it is taken up by plants in a similar way as CO2. To explore and verify the application of this novel tracer, it is highly desired to develop the ability to perform continuous and high-precision in situ atmospheric measurements of COS and CO2. In this study we have tested a quantum cascade laser spectrometer (QCLS) for its suitability to obtain accurate and high-precision measurements of COS and CO2. The instrument is capable of simultaneously measuring COS, CO2, CO and H2O after including a weak CO absorption line in the extended wavelength range. An optimal background and calibration strategy was developed based on laboratory tests to ensure accurate field measurements. We have derived water vapor correction factors based on a set of laboratory experiments and found that for COS the interference associated with a water absorption line can dominate over the effect of dilution. This interference can be solved mathematically by fitting the COS spectral line separately from the H2O spectral line. Furthermore, we improved the temperature stability of the QCLS by isolating it in an enclosed box and actively cooling its electronics with the same thermoelectric chiller used to cool the laser. The QCLS was deployed at the Lutjewad atmospheric monitoring station (60 m; 6°21′ E, 53°24′ N; 1 m a.s.l.) in the Netherlands from July 2014 to April 2015. The QCLS measurements of independent working standards while deployed in the field showed a mean difference with the assigned cylinder value within 3.3 ppt COS, 0.05 ppm for CO2 and 1.7 ppb for CO over a period of 35 days. The different contributions to uncertainty in measurements of COS, CO2 and CO were summarized and the overall uncertainty was determined to be 7.5 ppt for COS, 0.23 ppm for CO2 and 3.3 ppb for CO for 1-minute data. A comparison of in situ QCLS measurements with those from concurrently filled flasks that were subsequently measured by the QCLS showed a difference of −9.7 ± 4.6 ppt for COS. Comparison of the QCLS with a cavity ring-down spectrometer showed a difference of 0.12 ± 0.77 ppm for CO2 and −0.9 ± 3.8 ppb for CO.

Publisher

Copernicus GmbH

Subject

Atmospheric Science

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3