Eddy-covariance flux errors due to biases in gas concentration measurements: origins, quantification and correction
Author:
Fratini G.ORCID, McDermitt D. K., Papale D.ORCID
Abstract
Abstract. Errors in gas concentration measurements by infrared gas analysers can occur during eddy-covariance campaigns, associated with actual or apparent instrumental drifts or to biases due to thermal expansion, dirt contamination, aging of components or errors in field operations. If occurring on long time scales (hours to days), these errors are normally ignored during flux computation, under the assumption that errors in mean gas concentrations do not affect the estimation of turbulent fluctuations and, hence, of covariances. By analysing instrument theory of operation, and using numerical simulations and field data, we show that this is not the case for instruments with curvilinear calibrations; we further show that if not appropriately accounted for, concentration biases can lead to roughly proportional systematic flux errors, where the fractional errors in fluxes are about 30–40% the fractional errors in concentrations. We quantify these errors and characterize their dependency on main determinants. We then propose a correction procedure that largely – potentially completely – eliminates these errors. The correction, to be applied during flux computation, is based on knowledge of instrument calibration curves and on field or laboratory calibration data. Finally, we demonstrate the occurrence of such errors and validate the correction procedure by means of a field experiment, and accordingly provide recommendations for in situ operations. The correction described in this paper will soon be available in the EddyPro software (www.licor.com/eddypro).
Funder
European Commission
Publisher
Copernicus GmbH
Reference24 articles.
1. Arriga, N., Boschi, A., Tomassucci, M., Fratini, G., and Papale, D.: Uncertainty in eddy-covariance measurements due to instrumental setup and field deployment, in preparation, 2013. 2. Baldocchi, D. D.: Assessing the eddy covariance technique for evaluating carbon dioxide exchange rates of ecosystems: past, present and future, Global Change Biol., 9, 479–492, 2003. 3. Baldocchi, D.: "Breathing" of the terrestrial biosphere: lessons learned from a global network of carbon dioxide flux measurement systems, Aust. J. Bot., 56, 1–26, 2008. 4. Baldocchi, D., Detto, M., Sonnentag, O., Verfaillie, J., Teh, Y. A., Silver, W., and Kelly, N. M.: The challenges of measuring methane fluxes and concentrations over a peatland pasture., Agr. Forest Meterol., 153, 177–187, 2012. 5. Beer, C., Reichstein, M., Tomelleri, E., Ciais, P., Jung, M., Carvalhais, N., Rödenbeck, C., Arain, M. A., Baldocchi, D., Bonan, G. B., Bondeau, A., Cescatti, A., Lasslop, G., Lindroth, A., Lomas, M., Luyssaert, S., Margolis, H., Oleson, K. W., Roupsard, O., Veenendaal, E., Viovy, N., Williams, C., Woodward, F. I., and Papale, D.: Terrestrial gross carbon dioxide uptake: global distribution and covariation with climate, Science, 329, 834–838, https://doi.org/10.1126/science.1184984, 2010.
Cited by
4 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献
|
|