A Wide Field Auroral Imager (WFAI) for low Earth orbit missions
-
Published:2007-03-08
Issue:2
Volume:25
Page:519-532
-
ISSN:1432-0576
-
Container-title:Annales Geophysicae
-
language:en
-
Short-container-title:Ann. Geophys.
Author:
Bannister N. P.,Bunce E. J.,Cowley S. W. H.,Fairbend R.,Fraser G. W.,Hamilton F. J.,Lapington J. S.,Lees J. E.,Lester M.,Milan S. E.,Pearson J. F.,Price G. J.,Willingale R.
Abstract
Abstract. A comprehensive understanding of the solar wind interaction with Earth's coupled magnetosphere-ionosphere system requires an ability to observe the charged particle environment and auroral activity from the same platform, generating particle and photon image data which are matched in time and location. While unambiguous identification of the particles giving rise to the aurora requires a Low Earth Orbit satellite, obtaining adequate spatial coverage of aurorae with the relatively limited field of view of current space bourne auroral imaging systems requires much higher orbits. A goal for future satellite missions, therefore, is the development of compact, wide field-of-view optics permitting high spatial and temporal resolution ultraviolet imaging of the aurora from small spacecraft in low polar orbit. Microchannel plate optics offer a method of achieving the required performance. We describe a new, compact instrument design which can observe a wide field-of-view with the required spatial resolution. We report the focusing of 121.6 nm radiation using a spherically-slumped, square-pore microchannel plate with a focal length of 32 mm and an F number of 0.7. Measurements are compared with detailed ray-trace simulations of imaging performance. The angular resolution is 2.7±0.2° for the prototype, corresponding to a footprint ~33 km in diameter for an aurora altitude of 110 km and a spacecraft altitude of 800 km. In preliminary analysis, a more recent optic has demonstrated a full width at half maximum of 5.0±0.3 arcminutes, corresponding to a footprint of ~1 km from the same spacecraft altitude. We further report the imaging properties of a convex microchannel plate detector with planar resistive anode readout; this detector, whose active surface has a radius of curvature of only 100 mm, is shown to meet the spatial resolution and sensitivity requirements of the new wide field auroral imager (WFAI).
Publisher
Copernicus GmbH
Subject
Space and Planetary Science,Earth and Planetary Sciences (miscellaneous),Atmospheric Science,Geology,Astronomy and Astrophysics
Cited by
9 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献
1. Lobster Eye X-ray Optics;Handbook of X-ray and Gamma-ray Astrophysics;2024
2. The BepiColombo Mercury Imaging X-ray Spectrometer;Handbook of X-ray and Gamma-ray Astrophysics;2024
3. The BepiColombo Mercury Imaging X-Ray Spectrometer;Handbook of X-ray and Gamma-ray Astrophysics;2022-11-29
4. Lobster Eye X-ray Optics;Handbook of X-ray and Gamma-ray Astrophysics;2022
5. Photon Counting Imaging with Low Noise and a Wide Dynamic Range for Aurora Observations;Sensors;2020-10-21