Assessing accuracy of gas-driven permeability measurements: a comparative study of diverse Hassler-cell and probe permeameter devices
-
Published:2014-01-02
Issue:1
Volume:5
Page:1-11
-
ISSN:1869-9529
-
Container-title:Solid Earth
-
language:en
-
Short-container-title:Solid Earth
Author:
Filomena C. M.,Hornung J.,Stollhofen H.
Abstract
Abstract. Permeability is one of the most important petrophysical parameters to describe the reservoir properties of sedimentary rocks, pertaining to problems in hydrology, geothermics, and hydrocarbon reservoir analysis. Outcrop analogue studies, well core measurements, and individual sample analysis take advantage of a variety of commercially available devices for permeability measurements. Very often, permeability data derived from different devices need to be merged within one study (e.g. outcrop minipermeametry and lab-based core plug measurements). To enhance accuracy of different gas-driven permeability measurements, device-specific aberrations need to be taken into account. The application of simple one-to-one correlations may draw the wrong picture of permeability trends. For this purpose, transform equations need to be established. This study presents a detailed comparison of permeability data derived from a selection of commonly used Hassler cells and probe permeameters. As a result of individual cross-plots, typical aberrations and transform equations are elaborated, which enable corrections for the specific permeameters. Permeability measurements of the commercially available ErgoTech gas permeameter and the TinyPerm II probe permeameter are well-comparable over the entire range of permeability, with R2 = 0.955. Aberrations are mostly identified in the permeability range < 10 mD, regarding the TinyPerm II and the minipermeameter/Hassler-cell combination at Darmstadt University, which need to be corrected and standardized. Applying standardizations which consider these aberration intervals strongly improves the comparability of permeability data sets and facilitates the combination of measurement principles. Therefore, the utilization of such correlation tests is highly recommended for all kinds of reservoir studies using integrated permeability databases.
Publisher
Copernicus GmbH
Subject
Paleontology,Stratigraphy,Earth-Surface Processes,Geochemistry and Petrology,Geology,Geophysics,Soil Science
Reference39 articles.
1. Al Ajmi, H., Hinderer, M., Hornung, J., Bassis, A., Keller, M., Rausch, R., and Schüth, C.: Matrix versus fracture permeability in a regional sandstone aquifer (Wajid sandstone, SW Saudi Arabia), Grundwasser, in press, 2013. 2. Branets, L. V., Ghai, S. S., Lyons, S. L., and Wu, X.-H.: Challenges and technologies in reservoir modeling, Commun. Comput. Phys., 6, 1–23, 2009. 3. Chandler, M. A., Goggin, D. J., and Lake, L. W.: A mechanical field permeameter for making rapid, non-destructive, permeability measurements, J. Sediment. Petrol., 59, 613–615, 1989. 4. Corbett, P. W. M. and Jensen, J. L.: Variation of reservoir statistics according to sample spacing and measurement type for some intervals in the lower Brent Group, Log Analyst, 33, 22–41, 1992. 5. Darcy, H.: Les fontaines publiques de la ville Dijon, Dalmont, Paris, 674 pp., 1856.
Cited by
78 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献
|
|