Evaluation of the global-blockage effect on power performance through simulations and measurements
-
Published:2022-04-14
Issue:2
Volume:7
Page:875-886
-
ISSN:2366-7451
-
Container-title:Wind Energy Science
-
language:en
-
Short-container-title:Wind Energ. Sci.
Author:
Sebastiani AlessandroORCID, Peña AlfredoORCID, Troldborg NielsORCID, Meyer Forsting AlexanderORCID
Abstract
Abstract. Blockage effects due to the interaction of five wind turbines in a row are investigated through both Reynolds-averaged Navier–Stokes simulations and site measurements. Since power performance tests are often carried out at sites consisting of several turbines in a row, the objective of this study is to evaluate whether the power performance of the five turbines differs from that of an isolated turbine. A number of simulations are performed, in which we vary the turbine inter-spacing (1.8, 2 and 3 rotor diameters) and the inflow angle between the incoming wind and the orthogonal line to the row (from 0 to 45∘). Different values of the free-stream velocity are considered to cover a broad wind speed range of the power curve. Numerical results show consistent power deviations for all five turbines when compared to the isolated case. The amplitude of these deviations depends on the location of the turbine within the row, the inflow angle, the inter-spacing and the power curve region of operation. We show that the power variations do not cancel out when averaging over a large inflow sector (from −45 to +45∘) and find an increase in the power output of up to +1 % when compared to the isolated case under idealised conditions (neutral atmospheric conditions, no vertical wind shear or ground effects). We simulate power performance “measurements” with both a virtual mast and nacelle-mounted lidar and find a combination of power output increase and upstream velocity reduction, which causes an increase of +4 % in the power coefficient under idealised conditions. We also use measurements from a real site consisting of a row of five wind turbines to validate the numerical results. From the analysis of the measurements, we also show that the power performance is impacted by the neighbouring turbines. Compared to when the inflow is perpendicular to the row, the power output varies by +1.8 % and −1.8 % when the turbine is the most downwind and upwind of the line, respectively.
Publisher
Copernicus GmbH
Subject
Energy Engineering and Power Technology,Renewable Energy, Sustainability and the Environment
Reference33 articles.
1. Allaerts, D. and Meyers, J.: Boundary-layer development and gravity waves in
conventionally neutral wind farms, J. Fluid. Mech., 814, 95–130,
https://doi.org/10.1017/jfm.2017.11, 2017. a 2. Barthelmie, R. J., Hansen, K., Frandsen, S. T., Rathmann, O., Schepers, J. G.,
Schlez, W., Phillips, J., Rados, K., Zervos, A., Politis, E. S., and
Chaviaropoulos, P. K.: Modelling and measuring flow and wind turbine wakes in
large wind farms offshore, Wind Energy, 12, 431–444, https://doi.org/10.1002/we.348,
2009. a 3. Bleeg, J., Purcell, M., Ruisi, R., and Traiger, E.: Wind farm blockage and the
consequences of neglecting its impact on energy production, Energies, 11, 1609,
https://doi.org/10.3390/en11061609, 2018. a, b 4. Crespo, A., Hernández, J., and Frandsen, S.: Survey of modelling methods for
wind turbine wakes and wind farms, Wind Energy, 2, 1–24, 1999. a 5. Göçmen, T., Van der Laan, P., Réthoré, P.-E., Peña, A., Larsen, G., and
Ott, S.: Wind turbine wake models developed at the technical university of
Denmark: A review, Renew. Sust. Energ. Rev., 60, 752–769,
https://doi.org/10.1016/j.rser.2016.01.113, 2016. a
Cited by
6 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献
|
|