An electrospray chemical ionization source for real-time measurement of atmospheric organic and inorganic vapors
-
Published:2017-10-04
Issue:10
Volume:10
Page:3609-3625
-
ISSN:1867-8548
-
Container-title:Atmospheric Measurement Techniques
-
language:en
-
Short-container-title:Atmos. Meas. Tech.
Author:
Zhao YueORCID, Chan Jeremy K., Lopez-Hilfiker Felipe D., McKeown Megan A., D'Ambro Emma L.ORCID, Slowik Jay G., Riffell Jeffrey A., Thornton Joel A.
Abstract
Abstract. We present an electrospray ion source coupled to an orthogonal continuous-flow atmospheric pressure chemical ionization region. The source can generate intense and stable currents of several specific reagent ions using a range of salt solutions prepared in methanol, thereby providing both an alternative to more common radioactive ion sources and allowing for the generation of reagent ions that are not available in current chemical ionization mass spectrometry (CIMS) techniques, such as alkaline cations. We couple the orthogonal electrospray chemical ionization (ESCI) source to a high-resolution time-of-flight mass spectrometer (HR-ToF-MS), and assess instrument performance through calibrations using nitric acid (HNO3), formic acid (HCOOH), and isoprene epoxydiol (trans-β-IEPOX) gas standards, and through measurements of oxidized organic compounds formed from ozonolysis of α-pinene in a continuous-flow reaction chamber. When using iodide as the reagent ion, the HR-ToF-ESCIMS prototype has a sensitivity of 11, 2.4, and 10 cps pptv−1 per million counts per second (cps) of reagent ions and a detection limit (3σ, 5 s averaging) of 4.9, 12.5, and 1.4 pptv to HNO3, HCOOH, and IEPOX, respectively. These values are comparable to those obtained using an iodide-adduct HR-ToF-CIMS with a radioactive ion source and low-pressure ion–molecule reaction region. Applications to the α-pinene ozonolysis system demonstrates that HR-ToF-ESCIMS can generate multiple reagent ions (e.g., I−, NO3−, acetate, Li+, Na+, K+, and NH4+) having different selectivity to provide a comprehensive molecular description of a complex organic system.
Funder
National Science Foundation
Publisher
Copernicus GmbH
Subject
Atmospheric Science
Reference65 articles.
1. Aernecke, M. J., Mendum, T., Geurtsen, G., Ostrinskaya, A., and Kunz, R. R.: Vapor Pressure of Hexamethylene Triperoxide Diamine (HMTD) Estimated Using Secondary Electrospray Ionization Mass Spectrometry, J. Phys. Chem. A, 119, 11514–11522, 2015. 2. Aljawhary, D., Lee, A. K. Y., and Abbatt, J. P. D.: High-resolution chemical ionization mass spectrometry (ToF-CIMS): application to study SOA composition and processing, Atmos. Meas. Tech., 6, 3211–3224, https://doi.org/10.5194/amt-6-3211-2013, 2013. 3. Barrios-Collado, C., Garcia-Gomez, D., Zenobi, R., Vidal-de-Miguel, G., Ibanez, A. J., and Sinues, P. M. L.: Capturing in Vivo Plant Metabolism by Real-Time Analysis of Low to High Molecular Weight Volatiles, Anal. Chem., 88, 2406–2412, https://doi.org/10.1021/acs.analchem.5b04452, 2016. 4. Bean, H. D., Mellors, T. R., Zhu, J. J., and Hill, J. E.: Profiling Aged Artisanal Cheddar Cheese Using Secondary Electrospray Ionization Mass Spectrometry, J. Agric. Food Chem., 63, 4386–4392, https://doi.org/10.1021/jf5063759, 2015. 5. Berndt, T., Richters, S., Jokinen, T., Hyttinen, N., Kurten, T., Otkjaer, R. V., Kjaergaard, H. G., Stratmann, F., Herrmann, H., Sipila, M., Kulmala, M., and Ehn, M.: Hydroxyl radical-induced formation of highly oxidized organic compounds, Nat. Commun., 7, 13677, https://doi.org/10.1038/ncomms13677, 2016.
Cited by
20 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献
|
|