A Fourier transform spectroradiometer for ground-based remote sensing of the atmospheric downwelling long-wave radiance
-
Published:2019-01-30
Issue:1
Volume:12
Page:619-635
-
ISSN:1867-8548
-
Container-title:Atmospheric Measurement Techniques
-
language:en
-
Short-container-title:Atmos. Meas. Tech.
Author:
Bianchini GiovanniORCID, Castagnoli Francesco, Di Natale Gianluca, Palchetti LucaORCID
Abstract
Abstract. The Radiation Explorer in the Far Infrared – Prototype for Applications and
Development (REFIR-PAD) is a Fourier transform spectroradiometer that has
been designed to operate from both stratospheric balloon platforms and
the ground. It has been successfully deployed in a stratospheric balloon flight
and several ground-based campaigns from high-altitude sites, including the
current installation at the Italian–French Concordia Antarctic station. The
instrument is capable of operating autonomously with only a limited need of
remote control and monitoring and provides a multiyear dataset of
spectrally resolved atmospheric downwelling radiances, measured in the
100–1500 cm−1 spectral range with 0.4 cm−1 resolution and a
radiometric uncertainty of better than 0.85 mW(m2srcm-1)-1.
Publisher
Copernicus GmbH
Subject
Atmospheric Science
Reference50 articles.
1. Bhawar, R., Bianchini, G., Bozzo, A.,
Calvello, M. R., Cacciani, M., Carlotti, M., Castagnoli, F., Cuomo,
V., Di Girolamo, P., Di Iorio, T., Di Liberto, L., di Sarra, A.,
Esposito, F., Fiocco, G., Fuà, D., Grieco, G., Maestri, T.,
Masiello, G., Muscari, G., Palchetti, L., Papandrea, E., Pavese, G.,
Restieri, R., Rizzi, R., Romano, F., Serio, C., Summa, D., Todini,
G., and Tosi, E.: Spectrally Resolved Observations of Earth's
Emission Spectrum in the H2O Rotation Band,
Geophys. Res. Lett., 35, L04812, https://doi.org/10.1029/2007GL032207, 2008. a, b 2. Bianchini, G. and Palchetti, L.: Technical Note: REFIR-PAD level 1 data analysis
and performance characterization, Atmos. Chem. Phys., 8, 3817–3826, https://doi.org/10.5194/acp-8-3817-2008, 2008. a, b, c, d, e, f 3. Bianchini, G. and Raspollini,
P.: Characterization of instrumental line shape distortions due to
path difference dependent phase errors in a Fourier transform
spectrometer, Infr. Phys. Techn., 41, 287–292,
2000. a 4. Bianchini, G., Lanfranchi, M., and
Cortesi, U.: Flight qualification of a diode laser for path
difference determination of a high-resolution Fourier transform
spectrometer, Appl. Optics, 39, 962–965, 2000. a 5. Bianchini, G., Cortesi, U.,
Palchetti, L., and Pascale, E.: SAFIRE/A (spectroscopy of the
atmosphere by far-infrared emission – airborne): optimised
instrument configuration and new assessment of improved
performances, Appl. Optics, 43, 2962–2977, 2004. a
Cited by
17 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献
|
|