Abstract
Abstract. Aerosol loss in air intake systems potentially hampers the application of one-filter systems for progeny-based atmospheric 222radon (222Rn) measurements. The artefacts are significant when air has to be collected via long sampling lines, e.g. from elevated heights at tall tower observatories. Here we present results from a study, determining 222Rn progeny loss from ambient air sampled via 8.2 mm inner diameter (ID) Decabon tubing in the laboratory and from pre-installed 10 mm ID tubing at the Cabauw meteorological tower in the Netherlands. Progeny loss increased steeply with length of the tubing, decreasing sampling efficiency to 66 % for 8.2 mm ID rolled-up tubing of 200 m length at a flow rate of ca. 1 m3 h−1. Preliminary theoretical estimation of the loss yielded a sampling efficiency of 64 % for the same tubing, when taking into account turbulent inertial deposition of aerosol to the walls as well as loss due to gravitational settling. At Cabauw tower, theoretical estimates of the loss in vertical tubing with 10 mm ID and 200 m lengths with flow rate of 1.1 m3 h−1 yielded a total efficiency of 73 %, the same value as observed. 222Rn progeny loss increased strongly at activity concentrations below 1 Bq m−3. Based on our experiments, an empirical correction function for 222Rn progeny measurements when sampling through long Decabon tubing was developed, allowing correction of respective measurements for this particular experimental setting (tubing type and diameter, flow rate, aerosol size distribution) with an estimated uncertainty of 10–20 % for activity concentrations between 1 and 2 Bq m−3 and less than 10 % for activity concentrations above 2 Bq m−3.
Funder
Seventh Framework Programme
Reference24 articles.
1. Brockmann, J. E.: Sampling and transport of aerosols, in: Aerosol Measurement – Principles, Techniques, and Applications, edited by: Willeke, K. and Baron, P. A., Van Nostrand Reinhold, New York, 77–111, 2005.
2. Chambers, S., Williams, A. G., Zahorowski, W., Griffiths, A. D., and Crawford, J.: Separating remote fetch and local mixing influences on vertical radon measurements in the lower atmosphere, Tellus, 63, 843–859, 2011.
3. Hammer, S. and Levin, I.: Seasonal variation of molecular hydrogen uptake by soils inferred from atmospheric observations in Heidelberg, south-west Germany, Tellus B, 61, 556–565, https://doi.org/10.1111/j.1600-0889.2009.00417.x, 2009.
4. Jacob, D. J. and Prather, M. J.: Radon-222 as a test of convective transport in a general circulation model, Tellus B, 42, 118-134, 1990.
5. Jacobi, W. and André, K.: The Vertical Distribution of Radon 222, Radon 220 and their decay products in the atmosphere, J. Geophys. Res., 68, 3799–3814, 1963.
Cited by
6 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献