Can the Oxygenator Screen Filter Reduce Gaseous Microemboli?

Author:

Johagen Daniel,Appelblad Micael,Svenmarker Staffan

Abstract

Gaseous microemboli (GME) define small bubbles as <200 μm in size. GME are reported to increase morbidity after cardiopulmonary bypass (CPB) and cardiac surgery. To prevent intrusion of GME into the systemic circulation during CPB, arterial line filtration is generally recommended. New trends in oxygenator design promote location of arterial filtration as an integral part of the oxygenator housing. The present experimental study aimed to evaluate the GME removal properties of an integrated arterial screen filter in a standard microporous oxygenator. The GME properties of Terumo Capiox® FX25 with an integrated arterial screen filter was assessed in an experimental setup and compared with Capiox® RX25, in which no arterial screen filter is present. A blood analog prime solution was recirculated using a roller pump at 4 and 6 L per minute flow rate, respectively, through a customized CPB circuit comprising oxygenator, reservoir, and connecting tubing. A controlled volume of air was introduced into the circuit. The GME activity was measured and computed using a Gampt BCC200® ultrasonic device placing one probe at the venous inlet and one other at the arterial outlet of the oxygenator. Transmembrane delta values of GME activity were used to calculate the removal efficacy based on counts and volume of GME. Use of screen filtration reduced the GME volume by 99.1% ± .1% compared with 98.0% ± .1% for controls at 4 L/min flow rate (p< .001). At 6 L/min, the reduction was 97.9% ± .1% compared with 97.0% ± .1% (p< .001). In contrast, the reduction of GME counts was less effective after screen filtration compared with controls: 89.6 ± .6% versus 91.4 ± .4% at 4 L/min and 55.6% ± 1.6% versus 76.0% ± 1.4% at 6 L/min, respectively (p< .001). The tested oxygenator with incorporated arterial screen filter reduced GME activity based on the calculated volume at the same time as counts of GME increased.

Publisher

EDP Sciences

Subject

Cardiology and Cardiovascular Medicine,Health Professions (miscellaneous),Medicine (miscellaneous)

Cited by 3 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

1. Hypobaric type oxygenators – physics and physiology;Perfusion;2024-02-07

2. To Purge or Not to Purge;The Journal of ExtraCorporeal Technology;2020-03

3. Evaluation of CPB devices relative to their capabilities of reducing the transmission of gaseous microemboli (GME) to a patient during cardiopulmonary bypass;ANSI/AAMI/ISO TIR19024:2016; Evaluation of CPB devices relative to their capabilities of reducing the transmission of gaseous microemboli (GME) to a patient during cardiopulmonary bypass;2016-09-02

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3