To Purge or Not to Purge

Author:

Hugo Juan D. V.,Yeung Alexander,Weerwind Patrick W.

Abstract

To remove gaseous microemboli (GME) using an oxygenator with an integrated arterial filter, it is recommended by some manufacturers to purge the oxygenator as an additional safety feature while on bypass. In this in vitro study, we evaluated whether purging of oxygenators with an integrated arterial filter is efficient in reducing GME. Five different types of commercially available contemporary oxygenators with an integrated arterial filter based on progressive filter filtration (1), cascade filtration (1), screen filtration (2), or self-venting (1) were tested for their efficiency in removing GME while keeping the purge line open or closed. A bubble counter was used for pre- and post-oxygenator GME signaling, from which the filter efficiency was computed. Freshly drawn heparinized porcine blood was used at blood flow rates of 3 and 5 L/min. Three units of each oxygenator were tested with its specific reservoir at a fixed volume level of 1,500 mL. GME load was introduced into the venous line at 1,000 mL air/min. Measurements started as soon as GME were detected by the pre-oxygenator probe and then continued for 1 minute. There was no statistically significant difference in filter efficiency between the purged and non-purged groups for specific oxygenators. At a blood flow of 3 L/min, the average filter efficiency stayed approximately invariable when comparing the non-purged and purged groups, where 89.1–88.2% indicated the largest difference between the groups. At a blood flow rate of 5 L/min, the filter efficiency changed in one screen filter group from an average of 55.7% in the non-purged group to 42.4% in the purged group. Other filter efficiencies at the blood flow rate of 5 L/min for non-purged compared with purged groups were, respectively, 98.0 vs. 98.0% (screen filtration), 88.6 vs. 85.8% (self-venting filtration), 82.8 vs. 75.5% (progressive filter filtration), and 65.4 vs. 65.1% (cascade filtration). Based on these results, purging while confronted with continuous GME challenge did not result in an increased filter efficiency.

Publisher

EDP Sciences

Subject

Cardiology and Cardiovascular Medicine,Health Professions (miscellaneous),Medicine (miscellaneous)

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3