Turski Michał,Sekret Robert
Abstract
The aim of this article was to determine the energetic effect of adapting the control method of district heating substation to a solution using dispersed heat storage. The current control method of district heating substation uses the equations for regulating the temperature distribution of the installation water based on the value of the external temperature. This control method causes a significant amount of heat not consumed by end users. To adapt the control method to a solution using dispersed heat storage the following values were analyzed: the forecast of external temperature and duration of episodes with the lowest external temperatures on the heat output of the district heating substation based on 63 heating seasons. Obtained results were presented for a district heating substation in Poland. The analysis shows that a temperature of -15°C can be adopted as the reference to determine the expected heat output of the district heating substation. On this basis the demand for heat output for central heating purposes was 406 kW instead of 430 kW. The energetic effect of use dispersed heat storage to compensate the reduced heat output of the district heating substation was 24 kW with a compensation time of 24.2 h.
Reference38 articles.
1. Emission of pollutants in flue gases from Polish district heating sources
2. 4th Generation District Heating (4GDH)
3. Energy Efficiency Act of 20 May 2016 as implementation of Directive 2012/27/EU of the European Parliament and of the Council of 25 October 2012