Author:
Bujalski Maciej,Żyrkowski Maciej,Nabagło Daniel,Szczepanek Krzysztof
Abstract
The article deals with the problem of optimizing the operation of soot blowers in a pulverized coal-fired boiler based on the instantaneous degree of cleanliness of heating surfaces, determined in real time. The elaborated methodology of calculations and the algorithm that determines the optimal configuration of the blowers operation has been implemented and tested on a boiler with a capacity of 380 t/h. The indicator defining the degree of cleanliness of a given heating surface is calculated using available measurements of process parameters based on the epsilon-NTU method. The calculations are carried out in the DCS system for each surface individually (air and water heaters, evaporator, superheaters). During the standard operation of the boiler, the adopted methodology was verified, having analysed the usefulness of the tool to assess the boiler cleanliness under operating condition.
Reference12 articles.
1. Benson A. S., Jones M. L., Harb J. N., Ash Formation and Deposition, Fundamentals of Coal Combustion for Clean and Efficient Use, ELSEVIER, 299-373 (1993).
2. Shelby J. E., Introduction to Glass Science and Technology, Cambridge: The Royal Society of chemistry, (1997)
3. Seggiani M., Empirical correlations of the ash fusion temperatures and temperature of critical viscosity for coal and biomass ashes, Fuel (78), pp. 1121-1125, (4)
Cited by
2 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献