Abstract
Blood vessels exhibit highly nonlinear, anisotropic behaviour with numerous mechanical interactions. Since exact modelling of all involved effects would yield a computationally prohibitive procedure, a practical clinical simulation tool needs to account for a minimum threshold of relevant factors. In this study, we analyse needed modelling assumptions for a reliable simulation of the end-to-side anastomosis. The artery wall is modelled in a geometrically exact setting as a pre-stressed fibre-reinforced composite. The study focuses on the sensitivity analysis of post-anastomosis stress fields concerning the modelling assumptions. Toward that end, a set of full-scale finite element simulations is carried out for three sensitivity cases: (i) The post-operational stresses are estimated with and without taking the residual stresses into account, (ii) Different geometries of the cut in the recipient vessel are examined, (iii) The influence of errors in material stiffness identification on the post-operational stress field is estimated. The studied cases (i)–(iii) have shown a substantial impact of the considered modelling assumptions on the predictive capabilities of the simulation. Approaches to more accurate predictions of post-operational stress distribution are outlined, and a quest for more accurate experimental procedures is made. As a by-product, the occurrence of the pseudo-aneurysm is explained.
Funder
Russian Foundation for Basic Research
Subject
Modeling and Simulation,Applied Mathematics
Cited by
3 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献