Nitric Oxide on Extracorporeal Life Support-Circuit Modifications for a Safe Therapy

Author:

O’Meara Carlisle,Timpa Joseph,Peek Giles,Sindelar Melissa,Ross Jenny,Raper Justin,Byrnes Jonathan W.

Abstract

Nitric oxide (NO) incorporation into the sweep gas of the extracorporeal life support (ECLS) circuit has been proposed as a strategy to ameliorate the insults caused by the systemic inflammatory response. This technical study describes circuit modifications allowing nitric oxide to be incorporated into the circuit and describing and validating the oxygenator sweep flow rates necessary to achieve consistent safe delivery of the therapy. For patients requiring sweep rates less than 2 L/min, a simplified setup, incorporating a pressure relief valve/low flow meter in the gas delivery line, was placed in line between the blender/NO injector module and the NO sampling port/oxygenator. This setup allows titration of sweep to low flows without the need to blend in CO2 while maintaining the manufacturer recommendation of a minimum 2 L/min of sweep gas to safely deliver NO without nitric dioxide (NO2) buildup. This setup was tested three times at three different FiO2 rates and eleven different desired low sweep flows to test for reproducibility and safety to build an easy-to-follow chart for making gas flow changes. For patients requiring oxygenator sweep rates greater than 2 L/min, the pressure relief valve/low flow meter apparatus is not needed. Maintaining consistent sweep rate and nitric oxide delivery is required in order to utilize this therapy in ECLS. We demonstrated gas delivery across all flow rates. There were no issues delivering 20 parts per million of NO and negligible NO2 detection. The results from testing this setup were used to provide the specialist a chart at which to set the low flow meter to produce the desired flow rate at which the patient needs. This has been used clinically on 15 ECLS patients with success.

Publisher

EDP Sciences

Subject

Cardiology and Cardiovascular Medicine,Health Professions (miscellaneous),Medicine (miscellaneous)

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3