Zero-Balance Ultrafiltration during Cardiopulmonary Bypass Is Associated with Decreased Urine Output

Author:

Stammers Alfred H.,Tesdahl Eric A.,Mongero Linda B.,Patel Kirti P.,Petersen Courtney C.,Vucovich Jennifer Arriola,Jacobs Jeffrey P.

Abstract

Zero-balance ultrafiltration (ZBUF) during cardiopulmonary bypass (CPB) has been purported to reduce pro-inflammatory mediators during cardiac surgery. However, its clinical benefit is equivocal and its effect on renal function unknown. The purpose of this study was to examine the effect of ZBUF on urine output in adult patients undergoing CPB. Following institutional review board approval, 98,953 records from a national registry of adult patients at 215 U.S. hospitals between January 2016 and September 2019 were reviewed. Groups were stratified according to ZBUF use. Anuric patients were excluded from the study as they were patients with missing data on urine output, ultrafiltration use, or ZBUF volume. The primary endpoint was intraoperative urine output normalized to body weight and procedure duration (total operative time). Final analysis of this endpoint was carried out using a linear mixed-effects regression model adjusting for patient and procedural characteristics, as well as practice patterns associated with surgeons and perfusionists. There was a significant 16.1% reduction in median urine output for ZBUF patients (.94 [.54, 1.47] mL/kg/h) vs. the non-ZBUF group (1.12 [.70,−1.73] mL/kg/h), p < .001. After statistically adjusting for patient and procedural characteristics, each liter of ZBUF volume was associated with an estimated change in intraoperative urine output of −.03 mL/kg/h (95% CI: [−.04 to −.02], p < .001). The median ZBUF volume was 1,550 [1,000, 2,600] mL, and when ZBUF was used, conventional ultrafiltration (CUF) was more likely to be used as well (88.4% vs. 44.8%, p < .001). ZBUF patients had median asanguineous volume and crystalloid cardioplegia nearly two times more than non-ZBUF patients, and had slightly higher red blood cell transfusions (17.6% vs. 16.3%, p < .05). The application of ZBUF during CPB was associated with patients having lower urine output and significantly higher use of CUF. Further research is required to determine if these results are reproducible in prospective clinical studies.

Publisher

EDP Sciences

Subject

Cardiology and Cardiovascular Medicine,Health Professions (miscellaneous),Medicine (miscellaneous)

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3